EarthQuake W1000 Operator'S Manual & Parts List Download Page 9

ARDISAM

.com

Page 9

800-345-6007

EARTHQUAKE, Division of Ardisam, Inc.

ORDERING REpAIR pARTS

Parts can be obtained from the store where your mini log 
splitter was purchased or direct from the factory. To order 
from the factory, call or write to:

Please include the following information with your order:

1. Part numbers

2. Part description

3. Quantity
4. Model number and serial number

Ardisam, Inc.

 1690 Elm Street, Cumberland, WI 5489   

Phone (715) 8-415 Main Fax (715) 8-3  

800-345-6007

Email [email protected]

SERvICE INFORMATION

In the event you experience trouble operating your mini 
log splitter, follow the suggestions in the troubleshooting 
guide in this section.

The guide will help you pinpoint the causes of common 
problems and identify remedies.

For more complicated repairs you may want to rely on 
your retailer, an authorized mechanic, or Ardisam, Inc. 
(contact your retailer for a list of authorized mechanics in 
your area). A parts catalog is included in this section.

We will always be glad to answer any questions you 
have, or help you find suitable assistance. To order parts 
or inquire about warranty, call or write us at the address 
found in the next column, under the section ordering 
repair parts.

SERvICE, TROUblEShOOTING AND REpAIR

IN CASE OF A SERVICE PROBLEM, DO NOT SEND 
UNIT  BACK TO  RETAILER.  CONTACT  ARDISAM, 
INC.  AT  1-800-345-6007.  WE  WELCOME YOUR 

TROUblEShOOTING

Problem

Possible cause

Remedy/Action

Fails to split logs

The log pusher moves with a jerking 
motion, makes an unfamiliar noise or 
vibrates excessively

Oil leak occurs around cylinder ram or 
from other points

1. Refer to Log Splitter Operation Sec-
tion for perfect log loading
2. Reduce the log size before splitting 
on the log splitter
3. Refer to Sharpening Wedge Section 
to sharpen the cutting edge
4. Locate leak(s) and contact the dealer
5. Contact the dealer

1.  

Check oil level for possible oil 

refilling. Contact the dealer.

1. Loosen bleed screw 3-4 rotations 
before operating the log splitter
2. Tighten the bleed screw before mov-
ing the log splitter
3. Tighten the oil drain bolt with dipstick
4. Contact the dealer

1. Log is improperly positioned

2. The size or hardness of the log exceeds 
the capacity of the machine
3. Wedge cutting edge is blunt

4. Oil leaks

5. Unauthorized adjustment was made onto 
the maximum pressure limiting screw

1.  

Lack of hydraulic oil and excessive 

air in the hydraulic system

1. Air sealed in hydraulic system while oper-
ating
2. Bleed screw is not tightened before mov-
ing the log splitter
3. Oil drain bolt with dipstick is not tight
4. Hydraulic control valve assembly and/or 
seal(s) worn

ARDISAM

.com

Summary of Contents for W1000

Page 1: ...OMW1000 Rev 8 9 07 2007 Ardisam Inc All Rights Reserved ARDISAM com OPERATOR S MANUAL Parts W1000 4 Ton Mini Electric Log Splitter...

Page 2: ...st year from the date of purchase Ardisam will furnish 100 parts and labor to correct any defect caused by faulty material or workmanship All repairs made under warranty must have prior approval from...

Page 3: ...ety instructions which if not followed could endanger your personal safety Read and follow all instructions in this manual before attempting to operate this equipment Do not transport the log splitter...

Page 4: ...ctric Log Splitter 1 Turn off motor switch Unplug motor 2 Replace or repair the part on the log splitter 3 Check all parts that were repaired or removed during repair to ensure they are secure and fit...

Page 5: ...or 120V 50Hz 1500W IP54 Log Capacity Diameter 2 10 inches Length 20 inches Splitting Force 4 ton Hydraulic Pressure 2 300 psi Hydraulic Oil Capacity 3 75 quarts Overall Size Length 37 inches Width 11...

Page 6: ...table during log splitter operation Before moving the log splitter make sure the bleed screw is tightened to avoid oil leakage from this point CAUTION Failure to loosen the bleed screw will result in...

Page 7: ...at the same time FREEING A JAMMED LOG 1 Release both controls 2 Once the log pusher completely stops at its starting position insert a wood wedge under the jammed log 3 Start the log splitter to push...

Page 8: ...oil drain bolt and put it back into the oil tank 7 Make sure the level of the refilled oil is between the 2 grooves around the dipstick 8 Clean the oil drain bolt before re threading it back in Make...

Page 9: ...SERVICE TROUBLESHOOTING AND REPAIR IN CASE OF A SERVICE PROBLEM DO NOT SEND UNIT BACK TO RETAILER CONTACT ARDISAM INC AT 1 800 345 6007 WE WELCOME YOUR Troubleshooting Problem Possible cause Remedy A...

Page 10: ...EARTHQUAKE Division of Ardisam Inc ARDISAM com Page 10 800 345 6007 W1000 MINI ELECTRIC LOG SPLITTER BREAKDOWN MINIMUM ORDER 10 00...

Page 11: ...6 1 41 300141 circlip 1 42 300142 spring restore valve 1 43 300143 rod valve 1 44 300144 o ring 1 45 300145 sleeve valve 1 W1000 MINI ELECTRIC LOG SPLITTER PARTS LIST Key Part Description Qty 46 3001...

Page 12: ...disam Inc 1690 Elm Street P O Box 666 Cumberland Wisconsin 54829 800 345 6007 Fax 715 822 2223 E mail info ardisam com ARDISAM com Visit www ardisam com and discover more innovations that will benefit...

Reviews: