Special Features

Eight individual power supplies:

Rack mountable:

The  Cinénova-IR16  is  designed  with  8  individual  power 

supplies(bifilar)  for  power  isolation,  accuracy    and  better  channel 

This amplifier is designed to conveniently mount in commonly 

separation. 

used racks. 

Peak LED indicators:

 110V AC and 220V AC selectable:

The Cinénova-IR16 is equipped with 16 LED indicators on the 

The Cinénova-IR16 is factory preset to 110-120VAC. However, 

front panel. They show the operating status of each channel; the LEDs 

it  can  also  be  set  to  accommodate  220-240VAC  by  Earthquake 

will illuminate when the maximum recommended  output  is exceeded. 

authorized technician(s)/dealer(s).

If an LED is illuminated the majority of the time, it   indicates that the 
corresponding  channel  is  over-driven  (clipped).  The  input  to  the 

Remote zone control:

channel  must  be  reduced  to  eliminate  distortion  and  eventually,   
damages to the amplifier.

Each of the eight possible zones can be controlled by a wireless 

IR    remote  control.  Each  remote  has  the  ability  to  control  volume’s 

 Thermal protection:

up/down level, mute and also repeat the IR signal to other sources.

Each channel is equipped with a thermal sensor designed to 

Bus input:

shut  the amplifier down when it overheats. Overheating is not typical. It 
only occurs if the amplifier is over driven with low impedance speakers, 

This  feature  simplifies  installation  by  consolidating  several   

or if the amplifier is located in an improperly ventilated space.       

channels for one source. Simply plug the input source RCAs into the 
BUS input on the unit. Then switch the input source selector to BUS for 

 Individually selected and matched components:

as many channels are connected to the corresponding input source. 

Components  used  to  construct  the  Cinénova-IR16  are 

Bridgeable function (minimum impedance = 4-ohm):

subjected  to  an  exhaustive  selection  process;  during  which,  the 
components  are  matched  and  individually  tested  to  exact  tolerance. 

The Cinénova-IR16 delivers up to 8-zones, and can be bridged 

The  multi-layer,  glass-epoxy,  double  sided  printed  circuit  boards 

into several different configurations for higher power rooms.

exceed the standard stringent requirements by 50%.

4 or 8-ohm compatible:

8-Zones:

Since  speakers  are  manufactured  in  several  different 

impedance  ratings,  Earthquake  Sound’s  Cinénova-IR16  amplifier  is 

The Cinénova-IR16 delivers up to 8-zones, and several other 

designed to be 4 and 8-Ohm compatible. 

room combinations to better suite the your needs. 

Special Features

13

Summary of Contents for Cinenova IR16

Page 1: ...Will Move You 8 ZONES MULTI SOURCE IR DRIVEN AMPLIFIER USER S MANUAL Cin nova 16 IR Earthquake Sound Corporation 2727 McCone Avenue Hayward CA 94545 Phone 510 732 1000 Fax 510 732 1095 www earthquakes...

Page 2: ......

Page 3: ...tion Unpacking 4 5 6 7 Specifications 17 Product Warranty 19 Troubleshooting Maintenance 18 Front Rear Panel Overview Front Panel Map Rear Panel Map LOCAL Rear Panel Map BUS Keypad Remote Map Special...

Page 4: ...not correctly performed or adhered to could result in injury or death Calls attention to a procedure practice condition or the like that if not correctly performed or adhered to could result in damag...

Page 5: ...o not install near any heat sources such as radiators heat been spilled or objects have fallen into the apparatus the registers stoves or other apparatuses that produce heat apparatus has been exposed...

Page 6: ...s a LOCAL BUS input audio selector 12V DC trigger Individually driven amplifier blocks each block is driven by a discrete complementary output classA B stage with selected components Individual power...

Page 7: ...enix pad connectors 1 16 channelAmplifier Cin nova 16 included components IR There are several factors to consider before installing the Earthquake Sound Cin nova IR16 system What are the intended lis...

Page 8: ...C 18 375 466 5mm 17 431mm 19 482 6mm 4 101 5mm 6 876 174 5mm Front Rear Panel Overview 8 Earthquake Sound L M R L M R L M R L M R L M R L M R L M R L M R SPEAKER OUTPUT L L L L L L L L R R R R R R R R...

Page 9: ...ut unless this LED is ON Note When using another device to turn on the Cin nova IR16 amplifier this LED will come on when external device sends DC signal between 5 and 28V DC to the back ofTrigger con...

Page 10: ...removable conductors IR IN STATUS GROUND and CI Control Input these screw type connector accepts wire sized from 24 to 12 AWG We recommend using the CAT5 CAT5E CAT6 or CAT6E wires IR IN receive all t...

Page 11: ...n 5V DC and up to 28V DC This remote turn on option does not override the auto signal sensing turn on feature of this amplifier Note The front power switch page 9 feature 1 must be left in the OFF pos...

Page 12: ...eature 12 NOTE One Keypad is capable of driving multiple zones Simply connect the CI wire of those zones in parallel For example if you want to use the Keypad from zone 1 to control zone 1 through 5 r...

Page 13: ...hannel is equipped with a thermal sensor designed to Bus input shut the amplifier down when it overheats Overheating is not typical It only occurs if the amplifier is over driven with low impedance sp...

Page 14: ...te that you will need to use your source remote aim it at the pad and it will deliver the IR signal to the source Mono Stereo input control You must switch to MONO when the amplifier is wired for MONO...

Page 15: ...the back of the amplifier that can be connected to the source IR sensor Once connected the user can control the source from the room the illustration below has a DVD player connected to the IR repeate...

Page 16: ...R L M R L M R SPEAKER OUTPUT L L L L L L L L R R R R R R R R L R L R FUSE 110 120VAC 60Hz 220 240VAC 50Hz 75 Watts RMS Per Channel Background room s 6 Zones STEREO 150 Watts RMS Per Channel 1 High Pow...

Page 17: ...k 70 k 92dB 12 minutes 86dB 50V sec 29 200 8 5 5 28 VDC 15 Amp 120VAC 60Hz 10 Amp 220VAC 50Hz 115V T15A 250V 230 T10A 250V 3 AG type slow blow 5A 250V 61 7 lbs 28 kg 66 1 lbs 30 kg Date of purchase S...

Page 18: ...volume level to prevent damage to the unit Turn amplifier ON and circuit breaker shuts down This can either be a short in amp or poor circuit breaker in the house Plug amplifier into another outlet o...

Page 19: ...to resolve the problem over the phone thus warranty Customer will be charged a minimum of one 1 hour of labor at the eliminating the need to ship the product ongoing rates plus shipping charges back...

Page 20: ...he right to amend details of the specifications without notice Copyright Earthquake Sound Corporation Earthquake Sound Corporation 2727 McCone Avenue Hayward CA 94545 Phone 510 732 1000 Fax 510 732 10...