background image

 

PHXTI-IM (05/13)

 

 

Page 5

 

 

Figure 2. Typical Pool Installation Piping 

The heat exchanger water connections are nominal 2 inch PVC.  Plumb these connections first, as 
follows: 

 

1.  With abrasive cloth (Oatey #31411 or equivalent), roughen the ID surfaces of the female 

connectors on the heat exchanger and the OD surfaces on the water supply and return PVC 
pipes. 

2.  Clean the same surfaces in item 1 with PVC Cleaner (Oatey #30782 or equivalent) and 

allow to dry. 

3.  Apply PVC Cement (Oatey #30863 or equivalent) to the cleaned areas in step 2. 

4.  Be sure the correct water pipe is aligned with the correct connection on the heat exchanger. 

5.  Press one pipe at a time into the appropriate water fitting on the heat exchanger and 

maintain push pressure for 30 seconds. 

Summary of Contents for PHXTI Series

Page 1: ...rthlinked Technologies Inc EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual CONTENTS PAGE Pre Installation 3 Installation 3 Water Connections 4 Refrigerant Connections 7 Freeze Protec...

Page 2: ...CR equipment and in accordance with instructions set forth in this manual Earthlinked Technologies shall not be liable for any defect unsatisfactory performance damage or loss whether direct or conseq...

Page 3: ...eat exchanger is sold as a system component and must be sized and properly matched to other system components to provide the anticipated performance and safe operation of the system 2 Installation The...

Page 4: ...changer is shown in Figure 2 The heat exchanger is installed downstream of the filter and upstream of the water conditioning system The heat exchanger shall be no more than 10 feet from the heat pump...

Page 5: ...heat exchanger and the OD surfaces on the water supply and return PVC pipes 2 Clean the same surfaces in item 1 with PVC Cleaner Oatey 30782 or equivalent and allow to dry 3 Apply PVC Cement Oatey 30...

Page 6: ...PHXTI IM 05 13 Page 6 Figure 3 Heat Exchanger Refrigerant Connections...

Page 7: ...at will make the connections from the refrigeration system 2 Use 15 silver brazing alloy to seal the refrigeration connections 3 Make provisions to use the nitrogen brazing technique as described belo...

Page 8: ...PHXTI IM 05 13 Page 8 Figure 4 Wrap SWAGLOK Joints...

Page 9: ...PHXTI IM 05 13 Page 9 Figure 5 Apply Flame Retardant Shield...

Page 10: ...PHXTI IM 05 13 Page 10 Figure 6 Braze Joints...

Page 11: ...the filtration system continuously through the freeze period Generally during a light freeze circulating water will not freeze In areas where freezing conditions are prevalent and more severe implemen...

Page 12: ...PHXTI IM 05 13 Page 12 D Warranty All warranty claims shall be handled directly through AquaCal AutoPilot Inc...