Isokern Maximus Linear Series See-Thru Gas Fireplace
35
MFD – Vertical Termination Installation
1.
Before installing the MFD on the chimney, a power cable should be wired to the actuator and the actuator
cover should be secured (
Figure 27)
.
2.
Use 4-conductor cable (min. 18 AWG) with a weatherproof jacket such as rubber or silicone. Install a
weatherproof cable connector on the side of the actuator cover to prevent water ingress to the actuator.
3.
Use (6) of the included sheet metal screws to secure the actuator cover to the MFD. Once secure, apply a
bead of silicone around the seams of the cover.
4.
Mount the MFD outdoors at the top of the steel chimney run. Slide the collar of the MFD into the steel
chimney until the damper rests on the stop flange. Sheet metal screws may be installed around the collar
into the chimney for additional support.
FIGURE 27
FIGURE 28