background image

Caution

US Federal Law restricts this device to sale by or 

on the order of a Physician. 

The data acquired by  

the EarlySense System should be interpreted by 

a Health Care Professional only.

Intended Use

If using with EarlySense 2.0:

The EarlySense 2.0 System is intended for continuous measurement of 

respiration rate, heart rate and movement, in an automatic contact-

less manner, at home, hospital or clinic setting. The system is indicated 

for use in children, adolescents and adults. The operation of the 

EarlySense has been studied in children (weight ≥ 10 Kg) and adults  

(weight < 111 Kg) during sleep and resting condition. In addition,  

the EarlySense 2.0 System can continuously monitor oxygen saturation 

of arterial hemoglobin (SpO

2

) using pulse oximetry in pediatric 

 

(ages 2 years and older), adolescents, and adults at home, hospital, or 

clinical setting.

If using with EarlySense InSight:

The EarlySense InSight System is intended for continuous measurement 

of respiratory rate, heart rate and movement in an automatic contact-

less manner, in hospital or clinical setting. The system is indicated for use 

in children, adolescents and adults. The operation of the EarlySense has 

been studied in children (weight ≥ 10 Kg) and adults (weight < 111 Kg) 

during sleep and resting condition.

Explanation of System Labels

Caution

Manufactured by

Warning

Date of 

manufacture

Consult 

accompanying 

documents

MR Unsafe- Keep 

away from 

magnetic resonance 

imaging (MRI) 

equipment

Defibrillation 

proof, type BF, 

IP24 applied part 

Temperature 

limitation

Fragile, handle 

with care

Humidity limitation

Keep dry

Atmospheric 

pressure limitation

Indoor operation 

only

Rx Only

US Federal Law 

restricts this device 

to sale by or on the 

order of a physician

Non-ionizing 

Electromagnetic 

Radiation

This side up

Sorted disposal

IP24

Solid object 

protected and 

splash-proof 

accessory

Terms

HR

Heart Rate

RR

Respiratory Rate

 General Safety Guidelines

General Hazards

•  Do not use a damaged sensor. Use of damaged components might

result in malfunctioning of the system.

•  This Insert includes only instruction for use for the contact-free sensing 

element. For more detailed information and additional warning and

caution statement please refer to the system’s complete user manual. 

•  Handle the Sensing Unit with care. Do not drop, knock or shake the 

Sensing Unit. Rough handling can damage the internal circuit boards.

•  The Sensor is intended for indoor operation only.

•  A damaged sensor should not be disposed of as unsorted municipal 

waste. Contact your local distributor for unit disposal.

•  Changes or modifications not expressly approved by EarlySense Ltd. 

could affect the safety or effectiveness of the EarlySense Sensor

performance and void the warranty.

•  The EarlySense Sensing Units can be used with the EarlySense

products. 

•  The contact-free sensor is continuously operated equipment and is

water-proof splash (IP24).

Compliance with standards

System complies with IEC60601-1-1 and IEC60601-1-2

Electromagnetic Compatibility

This equipment complies with IEC 60601-1-2: for electromagnetic 

compatibility for medical electrical equipment and/or systems. 

 

This standard is designed to provide reasonable protection against 

harmful interference in a typical medical installation. However, because 

of the proliferation of radio frequency transmitting equipment and other 

sources of electrical noise in healthcare and other environments, it is 

possible that high levels of such interference due to close proximity 

or strength of a source might disrupt the performance of this device. 

Medical electrical equipment needs special precautions regarding EMC, 

and all equipment must be installed by qualified service personnel.

Contraindications for Use

The EarlySense Sensor is contraindicated for use in:

•  Patients in whom proper positioning cannot be achieved or

maintained.

•  Patients who do not meet the weight limits tested or specified.

•  An MR environment.

•  An explosive atmosphere or in the presence of flammable anesthetics 

or gases.

Warnings and Cautions

•  EarlySense System should be installed and serviced only by qualified 

service personnel authorized by the EarlySense Company.

•  In the event that sensor does not operate properly, contact Customer 

Support. 

•  Measurements may be affected by cable lengths. Do not shorten or

extend the lengths without authorized accessories.

•  Care should be taken for patients with poor bladder functioning or

control, including small children, when an EarlySense Sensor is placed 

under their mattress. 

•  Do not share the bed with another person or pet during

EarlySense System recording session. Sharing the bed could affect 

the effectiveness of the system and the accuracy of the measurements. 

•  Avoid using heating blankets. Use of heating blankets could affect the 

safety or effectiveness of the EarlySense System and void the system’s 

warranty.

•  Do not use the sensor for patients who weigh more than 200 kg

(440 Pounds). Usage of the System for such patients might result in 

malfunction of the Sensing Unit.

•  The patient should not have direct contact with the Sensing Unit. 

A mattress, mattress pad or mattress cover should always be placed 

as a barrier between the Sensing Unit of the EarlySense System and 

the patient. Patients should be frequently checked to ensure direct

contact does not occur.

•  Careful oversight should be provided when EarlySense System is used 

with children.

• The monitoring with contact-free sensor is not intended for

monitoring high risk situations where ECG monitoring is required. 

The most reliable method of patient monitoring combines close

personal surveillance with correct operation of the monitoring

equipment.

• The EarlySense technology and parameters have not been studied on 

any specific patient group, neither has it been studied as a diagnostic 

tool of any specific disease or medical condition. It is meant as an

adjunctive tool only for measuring respiratory rate, heart rate and

movement rate.

• As with all medical equipment, carefully route sensor cables and

connections to reduce the possibility of entanglement or strangulation.

Avertissements et mises en garde

• Le système EarlySense doit être installé et entretenu par un personnel 

de service qualifié uniquement, habilité par EarlySense Ltd. 

• Si le capteur ne fonctionne pas correctement, contactez le service

client.

• Les mesures peuvent être affectées par les longueurs de câble. 

Ne raccourcissez ni n’allongez les longueurs sans accessoires

autorisés. 

• Il convient de faire attention avec les patients ne contrôlant pas bien 

ou pas du tout leur vessie, notamment les jeunes enfants, lorsque 

le capteur EarlySense est placé sous le matelas. 

• Ne partagez pas le lit avec une autre personne ou un animal pendant 

une session d’enregistrement avec le système EarlySense. Le partage 

du lit peut nuire à l’efficacité du système et à la précision des mesures. 

• Évitez d’utiliser des couvertures chauffantes. L’utilisation de

couvertures chauffantes peut nuire à la sécurité ou à l’efficacité du

système EarlySense et annuler la garantie du système. 

• N’utilisez pas le capteur chez les patients pesant plus de 200 kg

(440 livres). L’utilisation du système chez ces patients peut provoquer 

un dysfonctionnement de l’unité de détection. 

• Le patient ne doit pas être en contact direct avec l’unité de détection. 

Un matelas, un surmatelas ou une housse de matelas doit toujours

être placé entre le capteur du système EarlySense et le patient.

Vérifiez régulièrement l’absence de contact direct entre le patient et 

le capteur. 

• Une surveillance rigoureuse est nécessaire lorsque le système

EarlySense est utilisé chez les enfants. 

• Le monitorage avec capteur sans contact n’est pas destiné à 

la surveillance de situations à haut risque lorsqu’un monitorage ECG 

est requis. La méthode de monitorage de patient la plus fiable allie

une surveillance individuelle rigoureuse et un bon fonctionnement de 

l’équipement de monitorage. 

• La technologie et les paramètres EarlySense n’ont pas été étudiés sur 

un groupe de patients spécifique. Ils n’ont pas non plus été étudiés en 

tant qu’outil de diagnostic pour une maladie ou un état pathologique 

spécifique. Il vise à être utilisé comme un outil supplémentaire

de mesure de la fréquence respiratoire, cardiaque et du taux de

mouvement. 

• Comme pour tout équipement médical, acheminez avec précaution

les câbles et les branchements afin de réduire le risque d’emmêlement 

ou d’étranglement. 

Positioning the Sensing Units

Place the Bed Sensing Unit under the patient’s mattress (at least 7 cm / 

3  inch thick) and locate it underneath the chest area of the patient 

horizontally.

Position the sensor so the top surface is facing upwards (as marked) 

Position the cord that connects the Sensor and the Bedside Unit so that 

it comes out from under the mattress at the head of the bed, in order 

to prevent interference with the movement of the patient getting in and 

out of bed.

If the sensor is placed on a metal framework that does not allow solid 

support for the sensor, please consult your authorized representative. 

Please make sure the sensor cable is not trailing on the floor.

How to use

1. Place the sensing unit under the mattress. 

2. Connect the EarlySense Sensing Unit to the designated connector on 

your compatible device.

3. Refer to the complete relevant system’s instruction for user, for proper 

system operation.

Sensor Components

• EarlySense Sensor 

• A detachable cable connecting the Sensing Unit (Sensor) to 

the Bedside Unit

Specifications

Physical Characteristics

Dimensions

420 

×

 210 

×

 14 mm

Weight

800 gr

Operating Conditions

Relative Humidity

30% - 95% non-condensing

Ambient Operating Temperature 5-40 °C (41-104 °F)
Atmospheric pressure

700-1060 hPa

Storage and Transportation Conditions

Temperature Range

-20-50 °C (-4-122 °F)

Relative Humidity

10%-90% non-condensing

Atmospheric pressure

500-1060 hPa

Cleaning and Disinfection of the Sensing Unit

Please follow your institution guidance for bed mattress cleaning, in 

order to clean the contact-less Bed Sensing Unit, that is placed under 

the bed mattress. Cleaning detergents such as soft, wipes containing 

alcohol, Chlorhexidine, Peroxide and bleach material or slightly damp 

cloth/wipes containing anti-septic substances can be used. Please 

ensure that the sensor is dry before re-use. Avoid excessive liquids.

Troubleshooting

For detailed troubleshooting please refer to system’s complete user 

manual.

Maintenance

Maintaining the required highest level of sensitivity necessitates a 

replacement of the sensor after 12 month of use. A clear notification is 

provided to the user, when sensor replacement is required.

Contact EarlySense

Israel

USA Office

EarlySense Ltd. (Manufacturer)

7 Derech Ze’ev Jabotinsky

Ramat Gan 5252007, Israel

Phone: +972-3-752-2330

Fax: +972-3-752-2340

800West Cummings Park, Suite 6400

 

 

 

 

Woburn, Massachusetts 01801, USA

Phone: +1-781-373-3228

Fax: +1-781-373-2367

E-Mail:[email protected]

www.earlysense.com

Mattress

Sensor under 

chest area

Reviews: