Mains connection 230V UK only

The stripper is supplied fitted with a 13 amp
plug top and fuse. If a replacement fuse is
required this must be rated at 13 amps. If in
doubt consult an electrician.
WARNING - THIS APPLIANCE MUST BE:
EARTHED. For your total protection it is
recommended that a residual current circuit
breaker (RCCB) should be used in
conjunction with the stripper; Min. 15 amp -
Max. 20 amp.
If any eletrical component is damaged or
faulty, it must be replaced by the
manufacturer or it’s appointed service agent
or a similarly qualified person in order to
avoid a hazard.
As the colours of the wires in the mains
lead of this appliance may not correspond
with the coloured markings identifying the
terminals in your plug, proceed as follows:

l

The wire which is coloured green and

yellow must be connected to the terminal in
the plug which is marked with the letter 

E

or

by the earth symbol, or coloured green
or green and yellow.

l

The wire which is coloured blue must be

connected to the terminal which is marked
with the letter 

N

or coloured black.

l

The wire which is coloured brown must be

connected to the terminal which is marked
with the letter 

L

or coloured red.

Mains connection 110V UK only

The stripper is fitted with a 16 amp
industrial plug for insertion into a suitable
transformer or generator supplying 110V
a.c. outlet. If this mains cable becomes
damaged it should be replaced with our Part
No. PS0155.

Extension Leads 230V

If you are using an extension lead it must
be rated at a 

minimum of 13 amps and

fully unwound.

Do not operate with a lead

rated at less than 13 amps as this will
cause premature failure of the element
which is not covered by guarantee.

EC Declaration of Conformity
We declare that the units: LCS conform to: 73/23/EEC, BSEN60335-2-15 & 89/336/EEC, EN55014-1, 
EN55014-2, EN61000-3-2, EN61000-3-3

Tim Hopper -Technical Director

Earlex Limited,

Moorfield Road, Slyfield Industrial Estate, Guildford, Surrey GU1 1RU. UK.

Tel: 01483 454666  Fax: 01483 454548

E-mail: [email protected]

Website: www.earlex.co.uk

© Earlex Limited 2004

PS3031  01/04

GUARANTEE

This product is guaranteed for a period of 2 years for ordinary use and 1 year for hire purposes or where the unit
is lent to other users. The tank is guaranteed against corrosion for 3 years. The guarantee is against faulty
materials or workmanship.
Whilst every possible care is taken by Earlex to ensure that our products leave the factory in good working order,
Earlex cannot under any circumstances accept liability for problems or damage caused by their 
subsequent use. It is the responsibility of the user to ensure that surfaces to be treated, cleaned or stripped are
suitable for steam.
This guarantee does not affect your statutory rights.
In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at
the address below together with a copy of your purchase receipt. All repairs will be dealt with speedily.
If the guarantee card is not returned within 14 days from the date of purchase the guarantee is limited to date of
product manufacture.

Summary of Contents for Pro-Steam LCS176

Page 1: ...in the best results please read the instructions before commencing any work Please also make a special note of the safety rules EARLEX LIMITED WILL ACCEPT NO RESPONSIBILITY FOR THE USE OF THIS PRODUCT IF USED FOR ANY OTHER PURPOSES THAN THOSE DETAILED HEREIN RETAIN FOR FUTURE REFERENCE OPERATING INSTRUCTIONS Models LCS270 LCS176 ...

Page 2: ...Be careful of overhead dripping when using on overhead areas tilt the steam plate away from the face and body and regularly empty the steamplate of any collected condensation l Do not leave unattended l Do not point the steam plate at anyone l Do not allow water or steam to enter light switches or sockets l Always use and store upright l Always visually check that the hose and steam plate inlet ar...

Page 3: ...O NOT USE ADDITIVES DO NOT OVERFILL Connect the mains lead from the unit to the socket and switch on The mains switch on the unit has a neon light and will light when the unit is on It will take between 10 and 20 minutes for the 230V unit or 25 35 minutes for the 110V unit to start producing steam depending on the temperature of the water used DO NOT LEAVE UNATTENDED Once steam is being produced a...

Page 4: ...ll with water and then switch on again the thermal cut out should automatically re set If this has not re set allow a further cooling period When you have finished using the unit allow any remaining water to cool and then empty the unit We recommend flushing the tank out with clean water before storing NEVER LEAVE WATER IN THE UNIT WHILST BEING STORED Storage Brackets are fitted to the frame for t...

Page 5: ...LY QUALIFIED ELECTRICIANS SHOULD UNDERTAKE THIS WORK Unit keeps cutting out l Check that water is above minimum level l Check that the extension lead is rated at 13 amps minimum and fully unwound 230V unit only l Check that no additives have been used Steam escaping from Pressure Cap l Check for blockages in hose or steam plate l Clean seating around cap area Descaling We recommend that the tank i...

Page 6: ...PS 0117 0 Ring Tank Seal 1 PS 0118 Gasket Tank Window 1 PS 0123 Thermostat 1 PS 0124 Tank Cover Black 1 PS 0127 Lock Nut M6 4 PS 0128 Protective Cover M6 2 PS 0134 Stainless Steam Pipe 1 PS 0136 Glass Window 1 PS 0137 Glass Retaining Plate 1 PS 0138 Level Indicator Ball 1 PS 0139 Screw for Retaining Plate 6 PS 0140 Screw for Tank Joint 3 PS 0155 Cable Assembly 110V 1 PS 0200 Steam Plate Buffer 1 P...

Page 7: ...0118 PS0019 PS0123 PS0006 PS0117 PS0020 PS0008 A PS0140 PS0042 PS0053 PS0049 PS0038 PS0202 PS0317 2750W x 230V PS0321 1760 x 110V PS0296 PS0023 PS0021 PS0022 PS0316 PS0032 PS0027 PS0302 PS0128 PS0127 PS0028 PS0029 UK PS0124 BLACK M IN M A X PS0022 PS0071 PS0004 PS0006 PS3006 PS3003 PS3001 PS3000 PS3005 PS0155 110V ...

Page 8: ...30V If you are using an extension lead it must be rated at a minimum of 13 amps and fully unwound Do not operate with a lead rated at less than 13 amps as this will cause premature failure of the element which is not covered by guarantee EC Declaration of Conformity We declare that the units LCS conform to 73 23 EEC BSEN60335 2 15 89 336 EEC EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 Tim Hopper T...

Reviews: