EN
12
HV2501EU
Problem
Cause
Remedy
Atomisation too
coarse
•
Viscosity of coating material too
high
•
Material volume too large
Material volume adjusting screw
turned too far to the right (+)
•
Nozzle contaminated
•
Air filter heavily soiled
•
Too little pressure build-up in
container
➞
Thin
➞
Turn material volume
adjusting screw to the
left (-)
➞
Clean
➞
Change
➞
Tighten container
Spray jet pulsates
•
Coating material in container
running out
•
Air filter heavily soiled
•
Nozzle seal is missing or worn
➞
Refill
➞
Change
➞
Insert an intact nozzle
seal
Coating material
causes "paint tears"
•
Too much coating material
applied.
➞
Turn material volume
adjusting screw to the
left (-)
Too much fog of
coating material
(Overspray)
•
Distance to the object too large
•
Too much coating material
applied
➞
Reduce distance
➞
Turn material volume
adjusting screw to the
left (-)
Paint in the
ventilating hose
•
Diaphragm soiled
•
Diaphragm defective
➞
Clean the diaphragm
➞
Replace the diaphragm
Poor covering
capacity on the wall
•
Spray material is too cold
•
Highly absorbent surface or paint
with poor covering capacity
•
Distance too large
➞
The material you are
spraying should be at
room temperature
➞
Cross spray (Fig. 8)
➞
Closer to the object
19. Technical Data
Technical Data
Max. viscosity
2700 mPas
Power source
230 V,
~ 50 Hz
Power consumption
320 W
Atomizing output
80 W
Max. flow rate
230 ml/min
Double insulation
Sound pressure level*
76 dB (A); Uncertainty K = 3 dB