 Dimension 
 

 

     Note: All Dimensions are in mm. 

 

      Front Panel 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

      
 
 

    
 Rear View 
 

 

 

       

 

 

 

Terminal Details 

 

1, 2         :  Source voltage      
                     
6             :  +12V 
7             :  Output 
8             :  GND 
 

8, 9          :  Short for – NPN and LIMIT SWITCH 
                   Open – PNP  
 

12, 10     :  RESET (short for atleast 250mS)   
11, 10     :  Short – HOLD  
                  Open – RESTART  
 
 3            :  NC 
 4            :  NO 

 

5            :  C 

  

NOTE:

  

Select PNP or NPN sensor/Limit switch before power ON. 

Connect Limit switch between 7 & 8. 

  

Wiring 

 

 
 

* Though the standard relay output rating is 5A,  

it is always necessary to use rated contactor to switch  

ON/OFF the load as shown above. 

This ensures healthyness of equipment in case of fault 

    short created on the power output lines. 
 
 
 
 
 
 
 
 
 

 

Programming Instruction : 

 

     Timing Example:- 

                                

Counts = 99999 

                                                   SENS = 100          

 

 

Press “SELECT” once, display shows “SET” for 2 seconds and then 
display shows previous set value with MSD flashing. 

 

Press “ADVANCE” till display shows 9. 

 

Press “SELECT” again; 2nd digit starts flashing. 

 

Press “ADVANCE” till display shows 9. 

 

Press “SELECT” again; 3rd digit starts flashing. 

 

Press “ADVANCE” till display shows 9. 

 

Press “SELECT” again; 4th digit starts flashing. 

 

Press “ADVANCE” till display shows 9. 

 

Press “SELECT” again; 5th digit starts flashing. 

 

Press “ADVANCE” till display shows 9. 

 

Press “SELECT” again; the set value is saved in memory and the 
display shows “SEnS” for 2 seconds and then display shows 
previous sensitivity value. 

 

Press “ADVANCE” till the display shows 100.        

 

Press “SELECT” display shows ‘00000’ to indicate counter is ready 
for operation. Same procedure shall be followed for different 
counts and sensitivity values. 

 

Contact Rating 

 

     

RLY 1C/O rated for 5Amps@250VAC/30VDC (NO) and 

     3Amps@250VAC/30VDC (NC) 

 

Disposition 

Once the product life is over, you may send back the  
 unit to EAPL for disposition.           
 