CREATED ON: April 28, 2016

 

                                                

Instruction Manual

 

 

 

 

 

EMS-01 V5.0 (24V DC) 

Multifunction Energy Meter 

  

                                         

 

                            

 

                                                                      

                                                            

EAPL

 

 
 

Introduction 

* : 

R,Y,B,Total  

**: Neutral current can be measured for unbalanced current   
      loads which are all 120° out of phase. 
***: R , Y, B 

 

        

 Box Accessories

 

     One (1) EMS-01(24V DC) digital meter         
     One (1) Instruction Manual 
     One (1) test report & calibration certificate for energy meter  
     Side Anchor (2 nos.) 

   

PARAMETERS 

PAGE 

 

BASIC  THD  TOTAL  IMPORT  EXPORT 

OLD  

TOTAL 

OLD 

IMPORT 

OLD  

EXPORT 

V

PP

*

, V

PN

*

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

*

, RPM, Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device ID 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hz 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW* 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KVAR* 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KVA* 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral Current**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage (%) *** 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current (%) *** 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KWh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KVrhC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KVrhI 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KVAh 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOAD HOURS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Safety Precautions

 

Read and follow all the safety precautions and instructions before 
installing and working with the equipment. 

                         !   

DANGER 

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH 

 

Apply appropriate personal protective equipment(PPE) and follow safety 
work practices 

 

Only qualified electrical workers should install this equipment. Such work 
should be performed only after reading this entire set of instructions. 

 

If the equipment is not used in the manner specified by the manufacturer, 
the protection provided by the equipment may be impaired. 

 

NEVER work alone. 

 

Turn OFF all power supplying the energy meter and the equipment in 
which it is installed before working on it. 

 

The successful operation of this equipment depends upon proper 
handling, installation and operation. Neglecting fundamental installation 
requirements may lead to personal injury as well as damage to electrical 
equipment or other property. 

 

NEVER bypass external fusing. 

 

NEVER short the secondary of PT 

 

NEVER open circuit a CT; use the shorting block to short circuit the leads of 
CT before removing the connection from energy meter. 

 

Before performing Dielectric or Megger testing on any equipment in which 
the energy meter is installed, disconnect all the input and output wires to 
the energy meter. High voltage testing may damage electronic 
components contained in the energy meter. 

 

The energy meter should be installed in a suitable electrical enclosure. 

Failure to follow these instructions will result in death or serious injury. 

 

EAPL is not responsible for any consequential damages arising out of use of 
our products, though the technology is cautiously chosen and 
implemented like any other well designed good electric meter.  

 
Installation

 

Connecting cable recommendations

 

 

Insulation rating 

Current rating 

Voltage circuit 

>600 VAC 

>0.1A 

Current circuit 

>600 VAC 

>7.5A/2.5mm

2

14AWG minimum 

 

Tools and Fasteners 

Kindly use star – type screw driver for tightening the screws. 
 

NOTE:

 Installation should include a disconnecting device, like switch or 

circuit breaker, with clear ON/OFF markings, to turn-off the auxiliary 
supply (control power).The disconnecting device should be within the 
reach of the equipment and the operator

.

 

 

 

 
Dimension 

 
 

       

         

Note: All Dimensions are in mm.

 

  

  Front Panel 

  

 

   

 

 

 

 

 

 

 

  

Rear Panel

 

 

OD RE KN 540011 REV 02/28-04-16

 

 

Page 1 of 2 

1. Top Display Window 
2. Bottom Display Window 
3. Previous button 
4. Scroll/Hold button 
5. Next button 
6. Select button 
7. Advance button 
8. Pulse Constant 