background image

Shower

 

head

Waterfall

OFF

ON

Jet

B

A

5

Installation

 

Instruction

 

6

OFF

ON OFF

ON

Shower

 

head

OFF

Jet

Two sets of the faucet:

A.The faucet is the function conversion.Turn 90° left is the

pipe cleaning function while 90° right is the shower head.

B.The cold-hot water inlet valve is both for hot and cold

water.The one with red label or with H mark is for hot
water,while the one with blue label or with C mark is for
cold water.You could adjust the label on the faucet to get
your wanted temperature.

Three sets of the faucet:

A.Function conversion value.Turn 90° left is the pipe

cleaning function while 90° right is the shower head.

B.The water-in pipe where with blue label is cold water,

and the hand-hole faucet with label C is also cold
water.Turning left could alternate the volume of the
cold water.The maximum is 90° to the left.

C.The water-in pipe where with red label is hot water,

and the hand-hold faucet with label H is also hot water.
Turning left could alternate volume of the hot water.
The maximum is 90° to the left.

The product designs for water going in from nozzle,also could be used to adjust shower head water in or water in from 
water outlet faucet.Water in from shower head is usually for body,head cleaning or etc.places.

Summary of Contents for AM189ETL-R

Page 1: ...Installation Instruction of AM189ETL R TS series Control panel ...

Page 2: ...FCI RCD earth leakage protection device socket 15 Warning To prevent electric shock please do not connect any extension cord to the power supply 16 Caution please use the product under the following condition water pressure is 0 15 0 40MPa the ground must have the ability to support the estimated load water can not exceed the overflow level the washroom need to reserve enough space for proper to h...

Page 3: ...1 Installation Instruction 2 AM189 R ETL Water and wire line instruction diagram ...

Page 4: ...ucet A Function conversion value Turn 90 left is the pipe cleaning function while 90 right is the shower head B The water in pipe where with blue label is cold water and the hand hole faucet with label C is also cold water Turning left could alternate the volume of the cold water The maximum is 90 to the left C The water in pipe where with red label is hot water and the hand hold faucet with label...

Page 5: ...ol panel Only can be matched the DC12V ozone generator 250 Crimp terminal 250 Crimp terminal 250 Crimp terminal 250 Crimp terminal Thermostatic power Main power Water pump power Electric parameter Spare part Parameter Rate voltage Rate voltage Rate power Massage pump Ozone generator Bottom light Thermostatic Control panel Speaker Note Electromagnetism valve TS Wiring Diagram ...

Page 6: ...ase volume The volume range is 0 20 8 6 Channel saving channel picking out the LCD flicker CH icon touch 8 6 1 Channel saving select the channel need to save when the radio turns on touch to choose the saving position the channel can be saved in this position when touch or for 2 seconds again The characteristics of the control system electrical box 1 AC220V 240V AC110V 120V Rated voltage 2 Rated f...

Page 7: ...r pause music 9 6 Touch bluetooth music playing function turns on LCD flicker VOL and number means the volume can be adjusted Touch or to adjust volume 10 Heater 10 1 The heater can not be turned on until the surfing water pump turns on 10 2 Touch to turn on the heater function LCD constant shows icon The heater would start or stop to work according to the o temperature inside the bathtub and the ...

Page 8: ...13 Installation Instruction 14 ...

Reviews: