Eagletone ParLED 36UV User Manual Download Page 8

User’s guide
Eagletone PARLED 36UV

 

User’s guide

 

Eagletone PARLED 36UV

6

7

ì

If you are using a controller with a 5-pin 
DMX output, you need to use a 5 to 3 pin 
adapter-cable.

ì

Connect  the  fixtures  together  in  a 
“daisy chain” via XLR plug cables, from 
the output of a fixture to the input of the 
next fixture. The cable cannot be bran-
ched or split to a “Y” cable. Inadequate 
or damaged cables, soldered joints or 
corroded connectors can easily distort 
the signal and shut down the system.

ì

The DMX output and input connectors 
are pass-through to maintain the DMX 
circuit when one of the units’ power is 
disconnected.

ì

At the last fixture, the DMX cable has 
to be terminated with a terminator to 
reduce signal errors. Solder a 120-ohm 
1/4W resistor between pin 2 (DMX-) and 
pin 3 (DMX+) into a 3-pin XLR-plug and 
plug  it  in  the  DMX-output  of  the  last 
fixture.

ì

Each lighting fixture needs to have an 
address set to receive the data sent by 
the controller. The address number is 

comprised between 0-511 (usually 0 & 
1 are equal to 1).

ì

3-pin  XLR  connectors  are  more 
common than 5-pin XLR ones.

ì

3-pin XLR: 

Pin 1: GND, 
Pin 2: Negative signal (-), 
Pin 3: Positive signal (+) 

ì

5-pin XLR: 

Pin 1: GND, 
Pin 2: Negative signal (-), 
Pin 3: Positive signal (+), 
Pin 4/5: not used

7. TROUBLESHOOTING

You  will  find  below  a  few  common 
problems that may occur during opera-
tion. Here are some suggestions to ease 
the troubleshooting:

The fixture does not work, no light 

ì

Check the connection to power and the 
mains fuse.

ì

Measure the mains voltage on the main 
connector.

Not responding to DMX controller

ì

DMX  LED  should  be  on.  If  not,  check 
DMX connectors and cables to see if the 
units are linked correctly.

ì

If  the  DMX  LED  is  on  but  there  is  no 
response  to  the  channel,  check  the 
address settings and the DMX polarity.

ì

If  you  have  intermittent  DMX  signal 
problems,  check  the  pins  on  the 
connectors or on the PCB of the fixture 
or the previous one.

ì

Try to use another DMX controller. 

ì

Check  if  the  DMX  cables  run  near  or 
alongside high voltage cables that may 
cause  damage  or  interference  to  the 
DMX interface circuit.

The device can’t slave to another one ? 

ì

You may have a breakage in the DMX 
cabling.

ì

Check the LEDs indicating response to 
the master/ slave mode signal and the 
DMX Adress

No response to the sound

ì

Make sure the fixture does not receive 
any DMX signal.

ì

Check  the  microphone  to  see  if  it  is 
sensitive to sound by tapping lightly on 
the microphone.

8. FIXTURE CLEANING

The cleaning of internal must be carried 
out periodically to optimize light output. 
Cleaning frequency depends on the envi-
ronment in which the fixture operates: 
damp,  smoky  or  par ticularly  dir ty 
surrounding can cause greater accumu-
lation of dirt on the fixture’s optics.

ì

Clean  with  soft  cloth  using  normal 
glass cleaning fluid.

ì

Always dry the parts carefully.

ì

Clean the external optics at least every 
20  days.  Clean  the  internal  optics  at 
least every 30/60 days.

6. DMX512 CONNECTIONS

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 chan-
nels.

3

1

2

1

3

2

1

3

2

8888

8888

8888

8888

DMX+

DMX Input

DMX Input

DMX Output

Termination reduces signal errors and avoids signal
transmission problems and interference. It is always
advisable to connect a DMX terminal.
(Resistance 120 Ohms 1/4W between pin2 (DMX-) and
pin3(DMX+) of the last fixture.)

DMX Output

Common

DMX-

Reviews: