GAS CONNECTIONS
Installation Personnel: Check all connections and fittings on valves and tubing supplied as a part
of this unit to make sure they did not come loose during shipment. A manual shutoff gas valve
should be provided upstream within 6 feet of the appliance for shutting the gas off during servicing.
A ground joint union should be provided between the house plumbing and the gas inlet to the
appliance. A gas pressure regulator has been provided as a part of this appliance. It is factory pre-
set for natural gas and is field adjustable for liquid propane gas. caution: never exceed 1/2˝ psig
inlet pressure! All plumbing should be clean and free of burrs and metal chips. All pipe connections
should be made using a pipe joint compound resistant to the action of LP gases. A drip TEE must be
used to collect any moisture or dirt in the gas. Upon completing the installation of this appliance, all
the gas connections must be checked for gas leaks. Use a solution of liquid dishwashing soap and
water to check for leaks. On models with safety pilot, check the lighter tube for correct position.
This installation must conform with local codes, or in the absence of local codes with the National
Fuel Gas Code ANSI Z223.1/NFPA 54, or the National Gas and Propane Installation code
CSA-B149.1 as applicable.
The appliance must be isolated from the gas supply piping system by closing it’s individual
manual shutoff gas valve during any pressure testing of the gas supply piping system at test
pressures equal to or more than 1/2˝ psig (3.45 kPa).
Provisions for proper air supply must be taken into account when installing the unit. Care should
be taken so as not to obstruct the area in front and in rear of the unit. DO NOT PLACE BACK OF
THE UNIT CLOSER THAN 10 INCHES TO A WALL OR OTHER SURFACES.
The appliance shall be located with respect to other equipment so it will have adequate
clearances for servicing and proper operation.
This unit is supplied with four (4) adjustable feet, which must be installed prior to operation. Four
(4) threaded openings are provided on bottom of the unit to accept the threaded portion of the feet.
Screw in the feet and tighten them securely. During operation, check the feet every sixty (60) days
to assure that they are tight. Failure to use the feet will void warranty and could cause unsafe
conditions.
NOTE: Appliance must be installed under a ventilation hood.
INSTALLING ADjUSTABLE FEET, REGULATOR, AND GREASE PAN/SLIDES
The following items are not installed at the factory and are shipped loose in the grease pan:
Adjustable Feet: This unit is provided with four (4) adjustable feet, which must be installed prior to
operation. Four (4) threaded openings are provided on bottom of the unit to accept the threaded
portion of the feet. Screw in the feet and tighten them securely. During operation, check the feet
every sixty (60) days to assure they are tight. Failure to use the Feet provided will void
the warranty and could cause unsaFe conditions.
Gas Pressure Regulator: The provided regulator is convertible for either Propane or Natural Gas.
Insure the regulator is set for gas being used. Install with appropriate sealing compound.
Grease Pan and Slides: The grease pan and slides must be installed before use. Left and right
slides are provided. These are installed on the underside of the unit with the six-(6) 10-32 screws
provided. Slide grease pan into position after installing slides.
LEVELING UNIT
Level unit by adjusting the four (4) feet, which have an adjustment of one inch for lineup with other
Eagle Countertop lines.