Note that the force of gravity is 1 g.   So, when configured for 2 g, the MicroSensor will easily be triggered by normal handling.  For 
example, lifting it at a rate that causes an additional 1 g of acceleration on the Z axis will trigger the sensor.   Along these lines, it is important 
to handle the sensor with care when reading the last session’s maximum values or 
they could be lost and replaced.      
 
To change the G-Force trigger value, connect the Standalone Cable as described 
above, but don’t power the G-Sensor.   Then, connect a small piece of wire between 
the unconnected pins of the Standalone Cable’s 4 pin connector, corresponding to the 
brown and yellow dots on the label, as shown in Figure 2.  This creates a jumper 
between the brown and yellow labeled pins.    
 
Then, power the G-Sensor via the Standalone Cable.   Upon power up, the LED will display the previous G-Force trigger value, and then 
flash the new value five times before beginning to display the last session’s max G-Force values.     Each time the power is applied with the 
jumper connected, the trigger value will increase by one, until reaching 5 g, at which time the trigger G-Force will return to 2 g.    To change 
the trigger value, just repeatedly disconnect and reconnect power, until the desired trigger value is flashed 5 times. 
 

Using the G-Sensor with your eLogger V4 or V3 

Windows Software and Firmware Update 

 

To use the G-Sensor with your eLogger, you must update your software to Eagle Tree Windows Software version 9.45 or later.   To 
update, download the latest software from the support page of our website, located at 

http://eagletreesystems.com/Support/apps.htm

 .    After 

downloading and installing the software, if you have not already done so, set up the Recorder software as described in your eLogger 
instruction manual.  Then the firmware of your eLogger will need to be updated.   To upgrade your firmware, just click “Hardware, 
Firmware Control” and click the Update button for the eLogger.  
 

Connecting the G-Sensor to the eLogger V4/V3 

 

The G-Sensor plugs into the “LCD/OSD” or “LCD/TX” port of your eLogger V4 or V3,  as shown in Figure 3.    If you have a PowerPanel 
or other MicroSensors, those can “daisy chain” connect to the pins on the side of your G-Sensor, with the polarity as indicated on the G-
Sensor label.   NOTE: The Standalone Cable must not be used when the G-Sensor is connected to the eLogger!

 

 
Configuring the G-Sensor with the Windows Software 

Choose one or more of the G-Sensor options below: 
 
Logging G-Force 
To log G-Force, just click “Hardware -> Choose Parameters to 
Log in the Recorder” and check the “3 Axis G-Force X, Y and 
Z” box.     
 
Displaying G-Force in the Windows Software 
To display the G-Sensor Gauge and/or Numeric G-Force 
readings, click “Software, Choose Instruments to Display on the PC Screen” and check one or more of the following: 
G-Force X Axis MeterG-Force Y Axis Meter, and/or G-Force Z Axis Meter 
G-Force X Axis NumericG-Force Y Axis Numeric, and/or G-Force Z Axis Numeric 
 
Then, after downloading data from your eLogger and clicking the “Play” button in the software,  or running the eLogger in USB Live Mode, 
the gauges and/or numeric displays will show the values corresponding to the G-Sensor readings. 
 
Graphing G-Force 
To graph G-Force, after downloading data from your eLogger, click “Data/2D Chart” and select G-Force XG-Force Y and/or G-Force Z 
for graphing.    Also note that live G-Sensor readings can be displayed on the graph, by clicking the “Live Mode” button on the chart. 
 
Displaying G-Force on the PowerPanel LCD 
Select “Hardware, Configure PowerPanel Display”, and choose G-Force X Axis,  G-Force Y AxisG-Force Z Axis for PowerPanel 
display. 

 

Using the MicroSensor with your own Firmware/Microcontroller 

Please see this document for information on using the MicroSensor with your own firmware: 
 

http://www.eagletreesystems.com/support/manuals/microsensor-i2c.pdf

 

Summary of Contents for GFORCE-HIGH

Page 1: ...ardware please open a support ticket with us at http ticket eagletreesystems com What the G Sensor Does The G Sensor is a precision 3 axis accelerometer that constantly measures change in acceleration in the X Y and Z axes The unit of acceleration measurement is the g which equals the force of gravity 9 81 m s2 So when the G Sensor reads 2 g for example this equals 2 times the force of gravity The...

Page 2: ...ession s maximum values with new readings after power is disconnected and reconnected The trigger G Force can be changed as described below Display of the Maximum Values Encountered After power up the G Sensor repeatedly displays the maximum values that were last captured cycling through the X Y and Z axes When displaying the values the LED first displays the axis symbol then the G Force reading f...

Page 3: ...l Then the firmware of your eLogger will need to be updated To upgrade your firmware just click Hardware Firmware Control and click the Update button for the eLogger Connecting the G Sensor to the eLogger V4 V3 The G Sensor plugs into the LCD OSD or LCD TX port of your eLogger V4 or V3 as shown in Figure 3 If you have a PowerPanel or other MicroSensors those can daisy chain connect to the pins on ...

Page 4: ...ing cost to us is your responsibility To obtain warranty service email support eagletreesystems com for further instructions This limited warranty does not cover The Software See the Software license agreement for more information on Software restrictions Problems that result from o External causes such as accident abuse misuse or problems with electrical power o Servicing not authorized by us o U...

Reviews: