BEFORE OPERATING THE MACHINE

Read the manual carefully and completely before attempting to operate the unit. This manual has
important information for the use and safe operation of the machine. Keep this manual handy at all
times. This machine will assure years of satisfactory service if operated and maintained according
to recommendations in this manual. If additional information is needed, please contact your local
distributor or write to:

Eagle Power Products
1174 Northland Drive
Mendota Heights, MN 55120

WARNING

The machine was designed for use on carpet, floor and upholstery extraction applications as
per instructions and recommendations written in this manual. Any deviation from its proper
use or purpose and the consequential damage that may occur is the sole responsibility of the
end user.

Disconnect the power cord from outlet before servicing. Do not leave machine connected to
an electrical outlet when unattended.

Do not immerse or use this machine in standing water. Such use may cause electric shock.

This equipment is not designed to handle or use combustible/volatile substances such as
gasoline or kerosene, in, on, or near the machine. The use of such materials will cause an
extreme hazardous condition.

When using an extension cord, use only a 3 conductor grounding cord - 12 ga. wire or
heavier. To avoid electric shock, do not expose the unit to rain - store it indoors only. Do not
use the machine for dry vacuuming.

Use defoamer at all times to prevent damage to the vacuum motor(s).

Do not use water in excess of 170°F (76°C).

To prevent seal damage and chemical buildup to the pump system, run clean water through
 the solution lines after each day’s use.

Use only commercially available carpet cleaning solutions and defoamer intended for use with
machines of this type. Do not use dyes, bleaches, ammonia or other additives. The use of
powdered cleaning solution if not diluted properly may result in damage to the pump. If
powdered chemicals are used, premix in a separate container before placing in the solution
tank.

Do not expose machine to freezing temperatures.

All repairs must be done by an authorized Eagle Power repair station.

Do not use replacement parts other than those specified on the parts list.

For units with heat :

Do not run heater dry.

Water hookups must be in place and water flowing through the heater prior to turning it on.
Failure to do so may cause internal component damage and will void warranty.

Heater must be filled with water or water based solutions at all times when in use.

Turn off the switch and unplug the heater from outlet when not in use, allow to cool before
cleaning.

Do not use heater at more than 300 PSI.

Do not immerse heater in water.

To avoid explosions and/or fire, do not use solvents or any flammable liquid in heater.

FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTIONS WILL
VOID THE WARRANTY

Summary of Contents for FASTRACTS BX12

Page 1: ...FASTRACTS BX12 Box Extractor With or Without Heat OPERATION AND PARTS MANUAL Rev A 11 2002...

Page 2: ...ctric shock do not expose the unit to rain store it indoors only Do not use the machine for dry vacuuming Use defoamer at all times to prevent damage to the vacuum motor s Do not use water in excess o...

Page 3: ...lar on the female quick disconnect fitting back Push the male fitting in and release the knurled collar until it snaps back 4 Make sure the drain valve is closed by pushing the T handle all the way in...

Page 4: ...method of cleaning the fabric If it calls for dry cleaning do not attempt to clean with the wet extraction method Otherwise damage to the fabric could occur Extraction works perfectly on most synthet...

Page 5: ...ed and built to require a minimum of maintenance But like any machine it does require some care to keep it in optimum working condition Careful attention to these maintenance instructions will give yo...

Page 6: ...ogged spray tips spray thru spray tips 2 Clogged solution intake filter screen 3 Plugged female quick disconnect coupler 4 Punctured pump diaphragm 100 psi only 5 Defective pump check valve 100 psi on...

Page 7: ......

Page 8: ...K00672 PVC PIPE 1 1 2 1 60 FT 20 K00741 PIPE ADAPTER 1 1 2 1 EA 21 Fl 1138 RECOVERY TANK 1 EA 22 K11185 ELBOW 90 1 1 2 MT MS PVC 1 EA 23 K00672 1 PVC PIPE 1 1 2 CUT TO 2 1 EA 24 A00051 ELBOW 90 1 4MP...

Page 9: ...LE 1 EA 58 Fl 1173 B HEATER TUNNEL COVER 1 EA 59 C11165 SCREW 8 X 1 4 EA 60 000293 SCREW 8 X 1 2 BLACK 2 EA 61 000295 1 SCREW 10 X 3 4 BLACK 2 EA 62 B00214 2 COVER SWITCH 3 EA 63 E010453 GASKET SWITCH...

Page 10: ......

Page 11: ...OLENOID 1 EA 19 A00161 TEE 1 4FP X 1 4FP X 1 4FP 4 EA 20 G11314 PRESSURE REGULATOR 1 EA 21 A00052 ELBOW 90 1 4FP X 1 4MP BRASS 6 EA 22 C00254 LOCKWASHER 1 4 SPLIT 8 EA 23 C02294 SCREW 1 4 20 X 1 1 4 2...

Page 12: ...1 4 MALE 1 EA 62 C11244 WASHER 1 2 ID X 1 1 2 OD 2 EA 63 630HR HEATER AUTOMOTIVE 1 EA 64 B11452 TWIST LOCK CONNECTOR 1 EA 65 B00221 1 POWER CORD 12 3 25 1 EA 66 C02305 CAP NUT 1 2 2 EA 67 G010313 WHE...

Page 13: ...returned within 30 days and is found defective the owner will be credited for the cost of the replacement part including shipping and handling Labor charges are covered for one year from the date of...

Reviews: