14
X9 Swing Rev - H
PHOTO EYE INSTALLATION
SW1
OFF
ON
OFF
OFF
OFF
ON
Monitoring Method
POWER
ALIGN
Min.
Max.
R.T:
Resistive
termination
Non-Polarity
Power
NO
NC
COM
(HB+) (HB-)
Switch Setting
Light ON
Dark ON
2 Frequency (HB)
3 Frequency (HB)
R. T. (NC)
R. T. (NO)
SW5
OFF
OFF
OFF
OFF
OFF
ON
SW2
OFF
OFF
OFF
ON
OFF
OFF
SW3
OFF
OFF
ON
ON
OFF
OFF
SW4
OFF
OFF
OFF
OFF
ON
OFF
ON
1 2 3 4 5
Pull Out
Lift Up
Remove Hood
Remove cover
with 4 screws
Cover
Pull Out
Closing
Opening
Open
Top View
5”
or less
Gate Frame
21”
Typical
MAX
27.5”
Disassembly
DIP-Switches
Beam Adjustment
Typical Vehicular Gate Locations
Mount with appropriate hardware
Wrap Around
Mounting Bracket
for Reflector
Wrap Around
Mounting Bracket
Max Sensing Range:
49 ft (15m) / Outdoors
Beam is aligned with reflector when yellow
ALIGN
LED turns
ON
.
Sensing Range Adjustment
Turning Clockwise: Range becomes longer.
Turning Counter-Clockwise: Range becomes shorter.
SW1
OFF
ON
OFF
OFF
OFF
ON
Monitoring Method
POWER
ALIGN
Min.
Max.
R.T:
Resistive
termination
Non-Polarity
Power
NO
NC
COM
(HB+) (HB-)
Switch Setting
Light ON
Dark ON
2 Frequency (HB)
3 Frequency (HB)
R. T. (NC)
R. T. (NO)
SW5
OFF
OFF
OFF
OFF
OFF
ON
SW2
OFF
OFF
OFF
ON
OFF
OFF
SW3
OFF
OFF
ON
ON
OFF
OFF
SW4
OFF
OFF
OFF
OFF
ON
OFF
ON
1 2 3 4 5
Side View
Hood
Cover
2 3/4”
4”
7 3/4”
1
2
5
6
8
9
12
13
7
10 11
3
4
14
COM
24 COM
+
+
+
24VDC
MAG LOCK
MOTOR
2 LIMITS
MOTOR
1 LIMITS
OPEN EXIT
MOTOR
COM
REVERSE
LOOP
5
4
3
2
1
10 11
9
8
7
6
14
13
12
SW 1 =
OFF
SW 2 =
OFF
SW 3 =
OFF
SW 4 =
ON
SW 5 =
OFF
Red
Blue
Black
White
Red -
Blue -
Black -
White -
9
11
12
14
Photo Ey
e Installation
Summary of Contents for X9S
Page 2: ...2 X9 Swing Rev H...
Page 33: ...31 X9 Slide Rev H...