background image

GARAGE  

MOTOR

1.

12

13

2.

1.

Putthewiresof thegateopener intotheirplaces(connector)

The outputs of the device are dry contact relay outputs. The inputs can only be driven by  
dry contactoutputs.
Each output and input reserves2 pinsin the connector of the device.Regarding the pinout  
of deviceplease checkthe wiringdiagramon pages 10-11.

The operation mode of the relay outputs can be configured in the application. Momentary
pulsemode with adjustable pulselengthor static on/off mode can be chosen.

NOTE:

Most of the garage door/gate openers are compatible with the pulse mode only

therefore it might be harmful for these devices to be used with on/off mode.Avoid switching
to static on/off mode unlessyou knowwhatyou are doing.

2.

Plugtheconnector intotheNoldOpendevice

The Nold Open must be connected to the appropriate points according to the connection  
drawing,with the control panel de-energized.

3. 

Fasten the wires with ascrewdriver

4. 

Mount NoldOpenonthewallwith2screws.

The device should be installed as close as possible to the entry zone and as far as possible
from metallic elements as they negatively affect the transmission distance of Bluetooth

®

signals. The device can be used both indoors and outdoors. In case of outdoor use, the
device must be fitted below a weatherproof protective cover. The device should be installed
at a heightof at least 1.5 metres above ground level.

For further information please visit

nold.io/help

Summary of Contents for EAGLE Open

Page 1: ...nesto control electronicdoors gates and barriers Please readthis UserGuide carefully before installing andusingtheproduct OPEN This devise can be used for Residential or Commercial applications Reside...

Page 2: ...Should any of these be missing from the package please immediatelycontactthedistributor byusing anyof thecontact details thatareoutlinedonthewebsite of theproduct Youwillalsoneed 4 Smallscrewdriver 5...

Page 3: ...e power supply output installed for this purpose on the connected control panel In the absence thereof an external power supply unit must be provided for operating the device whose output voltage is w...

Page 4: ...edpositionofthe controlled gateinassociationwithOUT1 type drycontact Theusageof theinputisoptional canbeenabled disabled in theapplication IN2 Secondinputof thedevicefor detectingclosedposition of the...

Page 5: ...ns andcompareit with this UserGuide andtheconnection drawing therein IN1 IN2 POWERSUPPLY OUT1 OUT2 GATE2 GATE1 OPTION1 TWO DIFFERENTGATES MAINCONTROL UNIT MAINCONTROL UNIT IN1 IN2 POWERSUPPLY OUT1 OUT...

Page 6: ...or thesedevicesto beusedwithon offmode Avoidswitching tostatic on offmodeunlessyouknowwhatyouaredoing 2 PlugtheconnectorintotheNoldOpendevice The Nold Open must be connectedto the appropriate points a...

Page 7: ...yourdevice NOTE The product can only be operated by the Nold application The manufacturer and distributor of Nold Open are not liable for anyerrors or damageby operation otherwise or bytheuseof anyhar...

Page 8: ...ight ison TheEAGLE Openpowersupply input is polarity independent LEDnotifications Pulsatinggreenlight Thedevice ispowered up ready touse Solidgreenlight Thedeviceisconnected to asmartphone Redlightint...

Page 9: ...functionalities are mapped into virtual keys in the application So the device can be controlled through these virtualkeys Virtualkeyscanbesharedwithother users NOTE Please do not share the virtual key...

Page 10: ...6 USENOLDCLOUD Tomanageyour devices andguests more easily use your Nold account to login to cloud nold io 20 21...

Page 11: ...Numberofswitchedoutput s 2 Outputtype unfused relay contact NO Max loadcurrent onoutput s 1A 24VDC 0 5A 125VAC Max switchedvoltage 125V AC 60V DC Numberofopendetection inputs 2 Inputvoltageshortcircu...

Page 12: ...es with applicable standards and normative documents and is equipped with the conformity marking The full conformity declaration is available at the followingwebsite nold io help The sign crossed dust...

Page 13: ...xternal impacts e g overvoltage lightning environmental effects chemical impacts e g acid rain scale etc irregular environmental conditions e g discoloration due to freezing or harmful solar radiation...