Eagle Access Control Systems Eagle I Manual Download Page 2

Slide Gate Operators 

Eagle I 

The Fail Secure System

The Fail Secure System allows you to manually open the gate with a use of a crank in case of an 

emergency. If a situation does arise, simply turn off the power switch and insert the crank at the 

opening on the side of the operator. As you continually turn the crank the gate will open. DO NOT try to 

crank the gate open when power is engaged.

Optional Release Procedure 

Using the Eagle-2070-Fire Box 

...,..,,.., 

:, 

.., 

.. ;,7 

.. 

,.,..,. 

------,

..,

..,"!

..,

�"l""!l""'l".,.'1!!!'1,... 

.. 

9"':',

').,.,. 

') ") '),. 

Pull Firmly On 

The "T" Handle 

To Release 

The Chain 

TURN THE POWER TO THE GATE OPERATOR OFF 

AND UNLOCK THE FIRE BOX 

-

· 

..

Mounting  The Secondary  Entrapment 

Note: Eagle Access Control Systems. Inc. 

recommends the installation of Edge Sensors 

on all sliding gate operator systems. 

All  Contact Sensors------\ 

Are Connected To 

Edge Sensor Inputs 

.. 

• 

EDGE SENSORS 

• 

(TOP VIEW) 

GATE OPENING 

• 

Eagle Operator 

Edge Sensors should be 

appropriately installed at 

recommended locations to 

ensure proper entrapment 

protection against injury. 

*

All Edge Sensors are shown

at recommended locations.

Eagle Access Control Systems,  Inc. 

(800) 708·8848 / www.eagleoperators.com 