Eachine WT50 Operating Manual Download Page 20

-

18

-

12. Warning and error messages

It incorporates a various functions of protective and monitoring the system to 

verify functions and the state of its electronics. In any case of occurring error, the 
screen displays the cause of error that is self- explanatory with audible sound.

Incorrect polarity connected.

Battery connection is interrupted.

Short-circuit of the output termination.

Input voltage wrong.

The voltage of the battery pack has been selected 

incorrectly!

The  charger  has  malfunctioned  for  some  reason. 

Seek professional advice.

The voltage is lower than which is set. Please check 

the number of cells in the battery pack.

The  voltage  is  higher  than  which  is  set.  Please 

check the number of cells in the battery pack.

Voltage  of  one  cell  in  the  battery  pack  is  too  low, 

please check the voltage of each cell.

Voltage of one cell in the battery pack is too high; 

please check the voltage of each cell.

Wrong connection of the connector detected; please 

check the connector and cable.

The internal temperature of the unit goes too high. 

Cool down the unit.

The processor cannot control the feeding current, 

please repair it.

Summary of Contents for WT50

Page 1: ...urchasing the balance charger This is a rapid charger discharger with built in balancer computerised with microprocessor and specialised operating software Please read this entire operating manual com...

Page 2: ...c o r p e h t g n i r u d n o i t a m r o f n i s u o i r a V 1 1 12 Warning and error messages 13 Speci cations 14 Warranty and service 6 1 Charging Lithium Battery 7 1 Charging NiCd NiMH battery 8 1...

Page 3: ...the cooling system is so ef cient that can hold such a power without any trouble of running the CPU or the operating program Individual voltage balancer for Lithium batteries inside It has an individu...

Page 4: ...e defect Input power monitor To protect the car battery using as input power from being damaged the voltage of it always monitored If it dorps below the lower limit the process will be ended automatic...

Page 5: ...2 Exterior of the unit Input power cable AC100 240V 3...

Page 6: ...g To avoid short circuits between the charge lead always connect the charge cable voltage level 1 2V cell allowable fast charge current 1C 2C depends on the performance of cell discharge voltage cut o...

Page 7: ...ily Some rechargeable batteries are said to have a memory effect If they are partly used and recharged before the whole charge is drawn out they remember this and next time will only use that part of...

Page 8: ...e Input Power Low Cut Off NiMH Sensitivity D Peak Waste Time CHG DCHG Nicd Sensitivity D Peak Temp Cut Off USB Enable Pb DISCHARGE NiMH CYCLE Nicd CYCLE Pb CHARGE SAVE DATA LOAD DATA LIXX CHARGE LIXX...

Page 9: ...up correctly If it is different from correct value the battery can explode during charge process It recognise the cell count of Lithium battery automatically at the beginning of charge or discharge p...

Page 10: ...ilize the optional software that can show you the charge process at PC You can set the maximum temperature at which the charger should allow battery to reach during charge Once a battery reaches this...

Page 11: ...d a constant voltage CV and constant current CC method The charge current varies according to the battery capacity and performance The nal voltage of charge process is also very important it should be...

Page 12: ...ode the charging process will be different from ordinary charging mode The internal processor of the charger will monitor the voltages of each cell of the battery pack and controls charging current th...

Page 13: ...again to start charging This shows the present state of FAST charging To stop charging arbitrary press Batt type Stop key once 6 4 STORAGE control Lithium battery This is for charging or discharging L...

Page 14: ...rage mode and discharge of Lithium battery pack It tries to normalise the voltages to be equal For this feature the individual plug of the battry pack should be connected to the individual port of the...

Page 15: ...ocessor at automatic charge mode But in Man mode it will charge the battery with the charge current you set at the display Each mode can be switched by pressing INC and DEC button simultaneously when...

Page 16: ...8 Pb lead sulphuric acid battery program This is programmed for charging Pb lead sulphuric acid battery with nominal voltage from 2 to 20V Pb batteries are totally different from NiCd or NiMH batterie...

Page 17: ...ey once The audible sound indicates you at the end of process 9 Save Data Program It has a data storage and load program for your convenience This feature can store up to 5 battery data by number that...

Page 18: ...sequence of charge and discharge and the cycling number Saving the data 10 Load Data Program This program calls back the data that was stored at Save Data program To load the data press Start Enter ke...

Page 19: ...ocessed It comes to the nal voltage when the program ended Displayed capacity cut off function is turn on and the setting value of capacity Displayed safety timer is turn on and duration of time in mi...

Page 20: ...ectly The charger has malfunctioned for some reason Seek professional advice The voltage is lower than which is set Please check the number of cells in the battery pack The voltage is higher than whic...

Page 21: ...cell 1 15cells 1 6Series 2 to 20V 400g 136 127 56mm We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational defe...

Page 22: ...RoHs...

Reviews: