background image

ENGLISH   3

ENGLISH   4

2. Main Unit Appearance

3. Outdoor Thermo Sensor

2.1 Part A- LCD

A1:  Outdoor Temperature                
A2:  Outdoor Humidity
A3:  Indoor Temperature                 
A4:  Indoor Humidity
A5:  Time Display                       
A6:  Barometer Pressure Trend      
A7:  Weather Forecast                    
A8:  Barometric Pressure Bar Graph   
A9:  Past Hour (Pressure History)         
A10: Absolute/ Relative Barometric  

 

 

Pressure Reading     

A11: Date, Day of Week

   

2.2 Part B- Buttons

B1:  “MODE/SET” button                   
B2:  “+ (12/24)” button

B3:  “ALARM ON/OFF” button               
B4:  “-” button   
B5:  “SNOOZE/LIGHT” button               
B6:  “HISTORY/WEATHER” button
B7:  “HPA/INHG/MMHG/

 (°C/ °F) button 

 

B8: “RELATIVE/ ABSOLUTE” button

B9:  “MAX/MIN/

” button                 

B10: “CHANNEL” button
B11: “RESET” button            

2.3 Part C - Structure

C1:  Wall Mount Hole                    
C2:  Battery Cover 
C3:  Stand

D1: Transmission Indication LED  
D2: Wall Mount Hole
D3: Channel Select Switch                  
D4: “RESET” button                         
D5: Battery Compartment                 

 

D6: Stand

4. Getting Started:

4.1 Main Unit:

 •

  Slide open main unit battery compartment cover [C2]

 •

  Insert 3 x AAA batteries observing polarity [ “+” and “ –“ marks]

 •

  Replace main unit battery compartment cover [C2]

 •

  Use a pin to press the RESET [B11] button on the rear of the main unit, the main unit is  

 

now ready for use

4.2 Outdoor Thermo Sensor

 •

  Batteries compartment (D5) of thermo sensor is locating behind the back cover,  

 

unscrews the batteries cover to open.

 •

   Insert 2 x AAA batteries observing polarity [ “+” and “–“ marks]

A1

C1

B1

B6

B3

B9

B5

B4

B10

B11

C2

C3

B2

B7

B8

A2

A3

A4

A5

A11

A7

A6

A9

A10

A8

Summary of Contents for DE908

Page 1: ...Slim Wireless Weather Station withTemperature Humidity Barometer Pressure User Manual DE908...

Page 2: ...pleasure to let you living better RUSSIAN 1 1 2 1 1 2 1 2 2 1 3 2 1 4 2 1 5 2 1 6 2 2 3 2 1 A 3 2 2 B 3 2 3 C 3 3 4 4 4 4 1 4 4 2 4 5 5 5 1 5 5 2 5 6 6 6 1 6 6 2 6 7 7 7 1 7 7 2 7 7 3 7 7 4 8 8 8 8 1...

Page 3: ...6 433 30 2 2 1 A A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 2 2 B B1 MODE SET B2 12 24 B3 ALARM ON OFF B4 B5 SNOOZE LIGHT B6 HISTORY WEATHER B7 C F HPA INHG MMHG C F B8 RELATIVE ABSOLUTE B9 MAX MIN B10 CHANNE...

Page 4: ...RUSSIAN 4 RUSSIAN 5 3 4 D1 D2 D3 D4 RESET D5 D6 4 1 C2 AAA C2 RESET B11 4 2 D5 AAA 5 5 1 C3 C1 5 2 30 30 12 C 30 C...

Page 5: ...A7 B7 B9 WEATHER B6 6 6 2 30 0 C RUSSIAN 6 RUSSIAN 7 7 7 1 A6 7 2 RELATIVE ABSOLUTE B8 ABS REL RELATIVE ABSOLUTE B8 3 B7 B9 RELATIVE ABSOLUTE B8 7 3 HISTORY WEATHER B6 12 A9 0 HR 1HR 1 2HR 2 C F HPA...

Page 6: ...BSOLUTE B8 MAX MIN B9 8 2 1 CHANNEL B10 3 CHANNEL 10 3 2 MAX MIN B9 MAX MIN B9 3 3 C F B7 LL L HH H 9 9 1 MODE SET B1 3 B2 B4 MODE SET B1 8 DCF 1 1 0 GE MO DI MI DO FR SA SO EN MO TU WE TH FR SA SU RU...

Page 7: ...T B1 3 B4 B2 MODE SET B1 1 2 ALARM ON OFF B3 SNOOZE LIGHT B5 5 7 MODE SET B1 12 24 B2 ALARM ON OFF B3 B4 10 11 SNOOZE LIGHT B5 5 12 Reset B11 80 158 19 0 C 50 C 32 F 122 F C F 20 99 637 787 5 3 Air Pr...

Page 8: ...7 9 Time Alarm Setting 9 1 Manual Time Setting 8 9 2 12 24 Hour Selection 8 9 3 Daily Snooze Alarm Setting 9 10 Low Battery Indication 9 11 Backlight 9 12 Precautions 10 10 1 Features 1 1 Weather Fore...

Page 9: ...HANNEL button B11 RESET button 2 3 Part C Structure C1 Wall Mount Hole C2 Battery Cover C3 Stand D1 Transmission Indication LED D2 Wall Mount Hole D3 Channel Select Switch D4 RESET button D5 Battery C...

Page 10: ...ecorded and shown on Barometric Pressure Bar Graph A8 The Graph is displayed in both hPa and inHg Indicating the barometric pressure trend is rising Indicating the barometric pressure trend is steady...

Page 11: ...r having more than one external transmitter Maximum3 select the Channel CH1 CH2 or CH3 to ensure each sensor is transmitting difference channel before inserting batteries The channel select switch D3...

Page 12: ...ata Temperature range 0 to 50 C 32 to 122 F Temperature Units Measured C or F switchable Humidity Range 20 to 99 Air Pressure Range 850 1050 hPa Air Pressure Units Measured mb hPa inHg mmHG switchable...

Page 13: ......

Reviews: