® 16k CL
45
UM 16kCL – REVC – 11/14
e2v semiconductors SAS 2014
12.3
Synchro and Acquisition
Feature
Commands
Description
LinePeriod
r tper
Get current line period
w tper <val>
Set line period, from from 1 (0,1µs) to 65535 (6553,5µs), step 1 (0,1µs)
LinePeriodMin
r tpmi
Get current line period min (0..65535 step 0,1µs)
AcquisitionLineRate
Xml Virtual
= 1 / LinePeriod en Hertz
ExposureTimeAbs
r tint
Get exposure time
w tint <val>
Set exposure time, from 1 (0,1µs) to 65535 (6553,5µs), step 1 (0,1µs)
TriggerPreset
r sync
Get trigger preset mode
w sync 0
Set trigger preset mode to Free run timed mode, with exposure time and
line period programmable
w sync 1
Set trigger preset mode to Triggered mode with exposure time settings
w sync 2
Set trigger preset mode to Triggered mode with maximum exposure time
w sync 3
Set trigger preset mode to Triggered mode with exposure time controlled by
one signal
w sync 4
Set trigger preset mode to Triggered mode with exposure time controlled by
two signals
w sync 5
Set trigger preset mode to Free run mode, with max exposure time and
programmable line period
12.4
Gain & Offset
Feature
Commands
Description
GainAbs
GainSelector= AnalogAll
r pamp
Get the current pre-amp gain
w pamp <val>
Set pre amplifier gain to: 0 (-12dB), 1 (-6dB), 2 (0dB) (analog gain)
Change balances and compensation
GainAbs
GainSelector= gainAll
r gain
Get current digital gain
w gain <val>
Set gain from 0dB(0) to +8 dB (6193)
Gain Abs
GainSelector=DigitalAll
r gdig
Get contrast expansion digital gain
w gdig <val>
Set contrast expansion digital gain from 0 (0 dB) to 255 (+14 dB), step 1
(TBD dB)
BlackLevelRaw
BlackLevelSelector=All
r offs
Get common black level.
w offs <val>
Set common black from -4096 to 4095, step 1
GainAbs
GainSelector=DigitalTap<j>
r fga<j> <val>
Get tap<j> digital gain. Dynamically updated on AnalogAll gain changes
w fga<j> <val>
Set tap<j> digital gain from -128 to 127 by step 1 (0.0021dB). Dynamically
updated on AnalogAll gain changes
ROI Gain Set
r roig
Read the last ROI gain set
w roig <val>
Set the Value for the ROI Gain : <val> from 0 to 2047 : U1.11
(1+coeff/1024) => x1..x1.999877 step 1/1024
ROI Set
r rois
Read the last ROI set
w rois <val>
Set the ROI and applies the ROI Gain on it.
<val> is a combination of Start and Stop Addresses for ROI.
- Start Address : From 0 to 16382 (0x0000 to 0x3FFE)
- Stop Address : From 1 to 16383 (0x0001 to 0x3FFF)