e2v DX600 Quick Start Manual Download Page 1

DX600

Circular Display and Calibration Board

for Infrared Gas Sensors

FEATURES

*

Compatible with e2v technologies TX600 transmitter board
and IR600 Series Infrared Gas Sensor Heads for Hazardous
areas.

*

Direct link to TX600 for display and calibration.

*

Menu driven by calibration pushbuttons.

*

Small size and low weight.

INTRODUCTION

The DX600 circular display board provides a calibration facility
for the TX600 Circular Transmitter Board and also provides a
loop monitor display. The DX600 is mounted directly above the
TX600 and is connected to it by a vertical 8-way double inter-
PCB connector. The whole assembly may be installed in an
explosion-proof enclosure. Refer also to the TX600 data sheet.

Following these specifications, the full calibration procedure is
explained.

GENERAL DATA

Dimensions:

length

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

70 mm

width

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

70 mm

height

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

22 mm

location slots .

.

.

.

.

.

.

.

.

.

.

11.5 x 6 mm

Weight .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

27 g

Power input .

.

.

.

.

.

5.0

+

0.25 V at 1 mA nominal

Power consumption

.

.

.

.

.

.

.

.

5 mW nominal

Signal input (link selectable) .

.

.

0.4 to 2.0 V loop monitor

0.4 to 2.0 V system monitor

Display type .

.

.

.

.

.

.

.

.

.

.

.

3.5 digit LCD

Display ranges (link selectable) .

.

.

.

.

.

.

. 0 to 100

0 to 200
0 to 500

Decimal point

.

.

.

.

.

.

.

.

.

link selectable DP2

Resolution

.

.

.

.

.

.

.

.

.

least significant digit

Indicators:

green flashing

.

.

.

.

.

.

.

.

.

.

.

.

.

OK

yellow

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

zero

yellow

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

span

red

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

fault

Switches .

.

.

.

.

.

.

.

.

.

.

.

.

.

4 x SPNO

for calibrate, up, down and system reset

Minimum underrange level

.

. 2.5 mA (

7

9.375% full scale)

Maximum overrange level

.

.

21.31 mA (108% full scale)

Fault indication .

.

.

.

.

.

.

.

.

.

.

red fault LED

display reads

7

12.5% full scale

Adjustment

.

.

.

.

.

.

4 mA back-off to zero display

span fine adjust on display

Temperature drift

.

.

.

.

.

.

+

0.2 counts/

8

C nominal

Temperature range:

operating

.

.

.

.

.

.

.

.

.

.

.

7

10 to +50

8

C

storage .

.

.

.

.

.

.

.

.

.

.

.

7

20 to +60

8

C

Humidity

.

.

.

.

.

.

. 15 to 95% RH, non-condensing

Connection

.

.

.

.

.

.

.

.

.

8 x 2-way DIL socket

#

e2v technologies (uk) limited 2007

A1A-DX600 Issue 3, May 2007

101159

e2v technologies (uk) limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU, UK

Telephone: +44 (0)1245 493493

Facsimile: +44 (0)1245 492492

e-mail: [email protected]