background image

 
 
 
 
 
 

 
E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com 

DC-001_Issue_O - Page 1 of 2 - QAF_252_Issue_5

 

EU Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 
Authorised Representative: 

E2S Warnsignaltechnik UG 

 

 

 

Charlottenstrasse 45-51 

 

 

 

72764 Reutlingen 

 

 

 

Germany 

 
Equipment Type:  

 

Electronic Sounders, Types BExS110D(-R)(-SIL), BExS120D(-R), 

 

 

 

Electronic Sounders, Types BExS110E(-R), BExS120E(-R), 

 

 

 

Loudspeakers, Types BExL15D(-R), BExL25D(-R), 

 

 

 

Loudspeakers, Types BExL15E(-R), BExL25E(-R),   

 

 

 

 

 

Appello Speech Sounders, Types BExA110(-R), 

 

 

 

Sontel, Types BExTS110D(-R), 

 

 

 

Hootronic Sounder, Types BExH120D(-R), 

 

 

 

Monitored Loudspeaker, Types BExL25GD(-R)

 

Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX) 

Notified Body for EU type Examination (Module B): 

Dekra Certification B.V. 
Notified Body No.: 0344 
Meander 1051, 6825 MJ Arnhem, The Netherlands 

EU-type Examination Certificate (Module B): 

KEMA 99ATEX6312X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 
based on 
quality assurance of the production process (Module D): 

Sira Certification Service 
Notified Body No.: 2813 
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands 

Quality Assurance Notification (Module D): 

SIRA 05 ATEX M342 

Provisions fulfilled by the equipment: 

II 2G Ex db IIB or IIC T4 Gb  
II 2G Ex db eb IIB or IIC T4 Gb 
II 2D Ex tb IIIC T100 ºC or T105 ºC or T115 ºC Db 

Standards applied: 

EN IEC 60079-0 : 2018 
EN 60079-1 : 2014 
EN 60079-7 : 2015 + A1 : 2018 
EN 60079-31 : 2014

 

Regulation EU No. 305/2011: Construction Products Regulation (CPR) 

 BExS110D24DC/BExS120D24DC (tones 2, 3, 9, 15, 16, 17) only 

Notified Product Certification Body for Certificate of Constancy of 
Performance or EC Type Examination Certificate and continuous 
surveillance, assessment and evaluation of factory production control: 

VdS Schadenverhütung GmbH 
Notified Body No.: 0786 
Amsterdamer Str 172-174, 50735 Köln, Germany 

Certificate of Constancy of Performance or EC Type Examination 
Certificate: 

0708-CPD-20225 

Standards applied: 

EN 54-3:2001 + A1:2002 

Directive 2014/90/EU: Marine Equipment Directive (MED) 

 part codes specified below only - BExS110D24DC-M only 

Notified Body for EU type Examination (Module B) and Conformity to 
EU-type based on quality assurance of the production process (Module 
D): 

DNV GL SE 
Notified Body No.: 0098 
Brooktorkai 18, 20457 Hamburg, Germany 

EU-Certificate Type Examination (Module B): 

MEDB00001BU 

EU Certificate of Conformity for the Quality Assurance System (Module 
D): 

MEDD00000GV 

Standards applied: 

EN 54-3:2014 incl. A1: 2019 
IEC 60092-504: 2016 

Summary of Contents for Sontel BExTS110DAC115

Page 1: ...rent at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used to run the equipment The power supply selected must have the necessary capacity to provide the i...

Page 2: ...eration and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas App...

Page 3: ...ghtened to ensure that the unit cannot move in service Fig 1a Fixing Location for Sounder Radial Fig 1b Fixing Location for Sounder Flare 7 Access to the Flameproof Enclosure To access the Ex d chambe...

Page 4: ...Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections sh...

Page 5: ...should be shorted In this mode of operation the selected tone pattern will pulse on and off following the telephone input signal Note if pulsed tone operation is selected it is advisable not to select...

Page 6: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Page 7: ...G TO BS8888 2000 GEOMETRIC TOLERANCES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFAC...

Page 8: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db eb IIB or I...

Page 9: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Page 10: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Page 11: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 12: ...Page left Intentionally blank...

Reviews: