INSTRUCTION & SERVICE MANUAL 
SONFL1H-HO Range - High Output Alarm Horn & L.E.D Beacon 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Please check factory settings and ensure the correct alarm tone is selected for your country or application 
 
Tone Selection / Header Pin Setting - Header pin settings are shown in the tone selection table. The links covered by the jumper are 
shown with a black rectangle. 
 

Torque 5Nm 

Disassembly 

Reassembly 

Mounting    See D242-05-501 

Loosen posi-pan screws 
in four positions to 
access enclosure 

Access to Enclosure 

98,0 [3,86]

Ø6.3 [0.25]

Cable Entry

Ø20.5mm [0.81"]

Rear Ø20mm Knockout
for M20 Cable Entry
if required

Pilot drilling positions
for internal mounting 
holes if required

Adhere supplied 

Gaskets to 

backboxes to 
maintain IP rating

800/1000 Hz @ 0.25 sec Alternating BS5839 Alarm Tone

500/1200 Hz @ 0.3 Hz 0.5 sec Slow Whoop NEN 2575:2000

544Hz (100mS)/440 Hz (400mS) AFNOR NF S 32-001

Simulated Bell Sound

Sweeping 800/1000 Hz @ 7 Hz Sweeping

500-1200 Hz 3.75 sec / 0.25 sec Australian Evacuation

Continuous 1000 Hz - PFEER toxic gas

Continuous 554 Hz

420 Hz @ 0.625 sec Australian Alert

1

2

3

4

5

6

7

8

9

Sawtooth 1200/500 Hz @ 1 Hz - DIN / PFEER P.T.A.P

10

8

8

8

1

1

9

10

Tone Description

Stage 1

Stage 2

-

-

-

99dB(A) @1m

100dB(A) @1m

99dB(A) @1m

97dB(A) @1m

95dB(A) @1m

99dB(A) @1m

100dB(A) @1m

100dB(A) @1m

97dB(A) @1m

97dB(A) @1m

SONF1 dB@ 1m

12V DC and 24V DC Tone Table 

DC

Tone
Settings

Tone 1

Tone 2

Tone 3

Tone 4

Tone 5

Tone 6

Tone 7

Tone 8*

Tone 9*

Tone 10*

*To set tones 8, 9 & 10 as first stage on DC, connect terminal ‘S2’ to ‘-’ terminal 

Beacon Flash Settings    See D228-00-001-IS 

Switch 

Se ng 

Flash Mode 

0 0 0

 

Steady on

 

1 0 0

 

Blinking

 

0 1 0

 

Flashing 1Hz*

 

1 1 0

 

Flashing 1.5Hz*

 

0 0 1

 

Flashing - Double Strike

 

1 0 1

 

Flashing - Triple Strike

 

0 1 1

 

Flashing 2Hz*

 

1 1 1

 

Flashing - Temporal

 

Voltage 

Intensity (cd) at 

1Hz flash rate 

Intensity (cd) at 

1.5Hz flash rate 

Intensity (cd) at 

2Hz flash rate 

12V dc 

5.9 

5.97 

6.35 

24V dc 

11.65 

12.32 

12.38 

115V ac 

12.99 

12.65 

14.1 

230V ac 

13.12 

13.22 

13.45 

On-axis Light Output Rating per UL1638 

1   2   3

ON

Flash Mode DIP Switch - 
Shown with 1-OFF, 2-ON, 3-
OFF (0 1 0), This denotes 
Flash mode 1Hz. For further 
flash modes refer to table. 

*Setting permitted for use as private 
mode fire alarm device 