Document No. D160-00-001-IS Issue C 08-01-20
Sheet 1 of 2
INSTRUCTION MANUAL
IS-pA1 Intrinsically Safe
ATEX and IECEx Panel Mount Sounder
1) Introduction
The IS-pA1 is an ATEX and IECEx certified intrinsically safe
Panel Mount Sounder which can produce a loud warning
signal in a hazardous area. The sounder has been designed
to operate in gas groups IIA and IIB via ATEX and IECEx
certified Zener Barriers or Galvanic Isolators. The sounder
may be tested or used in safe areas without using a Zener
Barrier or Galvanic Isolator,
2) Intrinsic Safety Certification
2.1 ATEX and IECEx certificates
SIRA 10ATEX2137
IECEx SIR 10.0073
The IS-pA1 sounder complies with the following standards:-
EN IEC 60079-0:2018
IEC60079-0:2017 (Ed7)
EN60079-11:2012
IEC60079-11:2011 (Ed6)
IEC60079-26:2014-10 (Ed3)
The sounder carries the Community Mark and subject to local
codes of practice, may be installed in any of the EEA member
countries. This instruction sheet describes installations which
conform to standard EN60079:14:2008 Electrical Installation
in Hazardous Areas. When designing systems for installation
outside the UK, the local Code of Practice should be
consulted.
1
The certification marking is as follows:
II 1G
2813
SIRA 10ATEX2137
IECEx SIR 10.0073
Ui = 40V Ii = 660mA Li = 0
Ex ia IIB T4/5/6 Ga (-40ºC <=Ta<= +60°C)
Ci = 32.5nF Pi
Determines T-Class, see certificate
WARNING:
TO AVOID A POSSIBLE ELECTROSTATIC
CHARGE ONLY CLEAN WITH A DAMP CLOTH
+ve
-ve
IS-pA1 Panel Mount Sounder
european safety systems ltd. London W3 7QH UK
10/1PS0001
e
2S
The equipment may be used in Zones 0, 1 and 2
with flammable gases and vapours
with Apparatus Groups IIA and IIB
Temperature Classes T1, T2, T3, T4, T5 and T6.
The equipment has the following safety
parameters:-
Ui = 40V
Ii = 660mA
Pi = See below
Li = 0
Ci = 32.5nF
With respect to Temperature Class the following
limitations on maximum input power P
i
are
applicable:
Temperature Class
Maximum input Power
P
i
T1, T2, T3, T4
1.3W
T5
0.6W
T6
0.3W
4
The equipment is only certified for use in ambient
temperatures in the range -40
o
C to +60
o
C and shall
not be used outside this range.
5
Installation of this equipment shall only be carried
out by suitably trained personnel in accordance with
the applicable code of practice e.g. IEC 60079-14 /
EN 60079-14.
6
Repair of this equipment is not possible and shall
not be attempted.
7
The equipment has not been assessed as a safety-
related device (as referred to by Directive 94/9/EC
Annex II, Clause 1.5).
8
The certification of this equipment relies on the
following materials used in its construction:
Enclosure:
ABS
Encapsulation:
Polyurethane casting compound
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility of
the user to take suitable precautions that prevent it
from being
adversely affected, thus ensuring
that the type of protection is not compromised.
“Aggressive substances” - e.g. acidic liquids or
gases that may attack metals, or solvents that may
affect polymeric materials
.
“
Suitable precautions” - e.g. regular checks as part of routine
inspections or establishing from the material’s data sheet that
it is resistant to specific chemicals.
2.2 Zones, Gas Groups and Temperature Class
The IS-pA1 sounder has been certified Ex ia IIB T4/5/6 and
when connected to an approved system it may be installed in:
Zone 0
explosive gas air mixture
continuously present.
II 1G Ex ia IIB T4/5/6 Ga (-40ºC
≤
Ta
≤
+60ºC)