background image

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. D160-00-001-IS       Issue C             08-01-20                       

Sheet 1 of 2

 

INSTRUCTION MANUAL 

IS-pA1    Intrinsically Safe  

ATEX and IECEx Panel Mount Sounder

 

 
 

 

 

1)  Introduction 

 
The IS-pA1  is an  ATEX  and IECEx certified intrinsically safe 
Panel Mount Sounder  which  can  produce a loud warning 
signal in a hazardous area. The sounder has been designed 
to operate in  gas groups IIA and IIB via  ATEX and IECEx 
certified  Zener Barriers or Galvanic Isolators.  The  sounder 
may be tested or used  in safe areas without using  a Zener 
Barrier or Galvanic Isolator, 
 

2)  Intrinsic Safety Certification

 

 

2.1 ATEX and IECEx certificates 
 

SIRA 10ATEX2137 

IECEx SIR 10.0073 

 

 

 
The IS-pA1 sounder complies with the following standards:-  
 
EN IEC 60079-0:2018 

IEC60079-0:2017 (Ed7) 

EN60079-11:2012 

IEC60079-11:2011 (Ed6) 

 

 

 

IEC60079-26:2014-10 (Ed3) 

 
The sounder carries the Community Mark and subject to local 
codes of practice, may be installed in any of the EEA member 
countries. This instruction sheet describes installations which 
conform to standard EN60079:14:2008  Electrical Installation 
in Hazardous Areas.  When designing systems for installation 
outside the UK, the  local Code of Practice should be 
consulted. 
 

The certification marking is as follows:  

II 1G

2813

SIRA 10ATEX2137

IECEx SIR 10.0073

Ui = 40V  Ii = 660mA  Li = 0

Ex ia IIB T4/5/6 Ga (-40ºC <=Ta<= +60°C)

Ci = 32.5nF  Pi 

Determines T-Class, see certificate

WARNING:

 TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

+ve

-ve

IS-pA1 Panel Mount Sounder

european safety systems ltd. London W3 7QH UK

10/1PS0001

e

2S

 

The equipment may be used in Zones 0, 1 and 2 

with flammable gases and vapours 

with Apparatus Groups IIA and IIB 

Temperature Classes T1, T2, T3, T4, T5 and T6. 

 

 

 

 

The equipment has the following safety 
parameters:- 

 

Ui = 40V  

Ii = 660mA 

Pi = See below

 

 

 

Li = 0 

Ci = 32.5nF 

 

With respect to Temperature Class the following 
limitations on maximum input power P

i

 are 

applicable: 

 

Temperature Class

 

Maximum input Power 

P

i

 

T1, T2, T3, T4 

1.3W 

T5 

0.6W 

T6 

0.3W 

 

The equipment is only certified for use in ambient 
temperatures in the range -40

o

C to +60

o

C and shall 

not be used outside this range. 

 

Installation of this equipment shall only be carried 
out by suitably trained personnel in accordance with 
the applicable code of practice e.g. IEC 60079-14 / 
EN 60079-14. 

 

Repair of this equipment is not possible and shall 
not be attempted. 

 

The equipment has not been assessed as a safety-
related device (as referred to by Directive 94/9/EC 
Annex II, Clause 1.5). 
 

The certification of this equipment relies on the 
following materials used in its construction: 

 

 

 

Enclosure:

 

 

 

 

 

ABS 

 

 

Encapsulation: 

 

 

 

 

Polyurethane casting compound 

 

If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being

 adversely affected, thus ensuring 

that the type of protection is not compromised. 

 

“Aggressive substances”   - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials

 

Suitable precautions” - e.g. regular checks as part of routine 

inspections or establishing from the material’s data sheet that 
it is resistant to specific chemicals. 
 

2.2  Zones, Gas Groups and Temperature Class 

The IS-pA1  sounder has been certified Ex ia IIB  T4/5/6  and 
when connected to an approved system it may be installed in: 
 
 

Zone 0 

explosive gas air mixture 

 

continuously present. 

 

II 1G        Ex ia IIB T4/5/6 Ga (-40ºC 

 Ta 

 +60ºC) 

Reviews: