No attempt should be made to repair a faulty IS-mB1
beacon. Suspect beacons must be returned to European
Safety Systems Ltd. or to your local agent for repair
.
13. GUARANTEE
Beacons which fail within the guarantee period should be
returned to European Safety Systems Ltd. or our local agent.
It is helpful if a brief description of the fault symptoms is
provided.
14. CUSTOMER COMMENTS
European Safety Systems Ltd. are always pleased to receive
comments from customers about our products and services.
All communications are acknowledged and whenever
possible, suggestions are implemented.
IECEx Approval
The IS-mB1 Beacon has also been approved to the IECEx
scheme.
The installation requirements for IS-mB1 beacons approved
to the IECEx scheme are the same as the installation
requirements for IS-mB1 beacons approved to the ATEX
directive.
Certificate No.
IECEx SIR 06.0045X
Marking:
Ex ia IIC T4 Ga (Ta = -40ºC to +60ºC)
Standards:
IEC 60079-0:2011
IEC 60079-11:2011
IEC 60079-26:2014-10
CONDITIONS OF CERTIFICATION (as stated on the IECEx
Certificate of Conformity IECEx SIR 06.0045X)
•
The equipment has an ingress protection rating of
IP65. However, if it has been supplied without a
cable entry device, then the user shall ensure that
the devices that are fitted will provide an ingress
protection that is appropriate to the environment in
which it is installed i.e. IP20 on better. If only one of
the two cable entries are used, then the unused
entry ‘knockout’ shall be left intact or fitted with a
blanking device that ensues ingress protection
appropriate to the environment in which it is installed
i.e. IP20 or better.
•
The enclosure is non-conducting and may generate
an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should
ensure that the equipment is not installed in a
location where it may be subjected to external
conditions that might cause a build-up of
electrostatic charges on non-conducting surfaces,
additionally, cleaning of the equipment should be
done only with a damp cloth.
The IS-mB1 beacons are marked with the certification
requirements for the ATEX and IECEx and approvals.
e
2S
european safety systems ltd.
London W3 7QH UK
www.e2s.com
WARNING:
TO AVOID A POSSIBLE ELECTROSTATIC
CHARGE ONLY CLEAN WITH A DAMP CLOTH
IS-mB1 Beacon
II 1G Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)
0518
SIRA 05ATEX2084X
Year / Serial No. 09 / 1MBR000001
IECEx SIR 06.0045X
Ui = 28V Ii = 660mA Pi = 1.2W
Ci = 0 Li = 0
FM Approval
The IS-mB1 Beacon has also been FM Listed.
Marking: IS Class I, Zone 0, AEx ia IIC T4
IS Class I, Division 1, Groups A, B, C, D
See the Control Drawings D 5036 Sheets 1 and 2 for
installation details and entity parameters.
WARNINGS:
IS-mB1 Beacon
To prevent ignition of flammable or combustible
atmospheres, disconnect power before servicing
Substitution of components may impair safety
FM
APPROVED
IS Class l, Division 1, Groups A, B, C, D
IS Class I, Zone 0, AEx ia IIC T4 (-40ºC <=Ta<= +60°C)
e
2S
european safety systems ltd.
London W3 7QH UK
Control Drawing D 5036
www.e2s.com
Year / Serial No. 09 / 1MBR000001
TO AVOID A POSSIBLE ELECTROSTATIC
CHARGE ONLY CLEAN WITH A DAMP CLOTH
Summary of Contents for IS-mB1 Minialite
Page 5: ......