background image

 

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]                 Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com                Fax: +44 (0)20 8740 4200 
Document No. IS 5002      Issue G             25-01-2018                       Sheet 1 of  4

 

INSTRUCTION MANUAL 

IS-mB1    Min

ia

lite 

Intrinsically Safe Round LED Beacon

 

 
 
 

                 

 

 
 
 
 
 

 
1.  INTRODUCTION 

The IS-mB1 is an ATEX and IECEx certified intrinsically safe 
beacon  which  will  produce  a  visual  warning  in  a  hazardous 
area.  Red,  Amber,  Green  and  Blue  output  models  are 
available. 
   

 

2. DESCRIPTION 

The  device  will  start  to  flash  when  power  is  applied  to 
ter and -. The beacon has two flash rates one double 
flash  per  second  and  two  double  flashes  per  second.  The 
flash  rate  is  selected  by  setting  an  internal  pin  header.  The 
unit is factory set to produce two double flashes per second. 
 

3. SUPPLY VOLTAGE 

The  IS-mB1  beacon  has  been  designed  to  operate  in  a 
hazardous area via 28V 300 ohm ATEX and IECEx certified 
Zener  Barriers  or  Galvanic  Isolators.  The  beacon  may  be 
tested  or  used  in  safe  areas  without  a  Zener  Barrier  or 
Galvanic  Isolator,  but  at  supply  voltages  above  16V  the 
internal  current  limit  will  function  and  the  brightness  may  be 
reduced.     The  beacon should  not  be  continuously  operated 
without a barrier or isolator with a supply voltage greater than 
16V.  
 

4. INTRINSIC SAFETY CERTIFICATION 

 

4.1 ATEX certificate 

The IS-mB1 beacon complies with the following standards:-  
 
EN60079-0:2012  
EN60079-11:2012 
IEC60079-26:2014 
 
 

 

 
The  EC-Type  Examination  Certificate  SIRA  04ATEX2084X 
has  been  issued  by  the  Notified  Body  Sira.  This  confirms 
compliance  with  the  European  ATEX  Directive  94/9/EC  for 
Group  II,  Category  1G  equipment.    The  beacon  carries  the 
Community Mark and subject to local codes of practice, may 
be installed in any of the EEA member countries. 

 
 
This  instruction  sheet  describes  installations  which  conform 
to  EN60079:Part14:2008  Electrical  Installation  in  Hazardous 
Areas.    When  designing  systems  for  installation  outside  the 
UK, the local Code of Practice should be consulted. 
 

1)  The certification marking is as follows:  

e

2S

european safety systems ltd. 

London W3 7QH UK
www.e2s.com

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

IS-mB1 Beacon

II 1G     Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)

0518

SIRA 05ATEX2084X

Year / Serial No. 09 / 1MBR000001

IECEx SIR 06.0045X

Ui = 28V  Ii = 660mA  Pi = 1.2W
Ci = 0  Li = 0

 

 

2)  The  equipment  may  be  used  in  zones  0,  1  and  2 

with  flammable  gases  and  vapours  with  apparatus 
groups  IIA,  IIB  &  IIC  and  with  temperature  classes 
T1, T2, T3 and T4. 

3)  The  equipment  is  only  certified  for  use  in  ambient 

temperatures  in  the  range  -40

o

C  to  +60

o

C  and 

should not be used outside this range. 

4)  The  certificate  number  has  an  ‘X’  suffix,  which 

indicates  that  the  certificate  contains  one  of  more 
special  conditions  for  safe  use.  Those  installing  or 
inspecting the equipment should refer to this section 
of the certificate. 

5)  The equipment has not been assessed as a safety-

related  device  (as  referred  to  by  Directive  94/9/EC 
Annex II, clause 1.5). 

6)  Installation of this equipment shall be carried out by 

suitably-trained personnel in accordance with the 
applicable code of practice. 

7)  Repair of this equipment shall only be carried out by 

the manufacturer or in accordance with the 
applicable code of practice. 

8)  The certification of this equipment relies on the 

following materials used in its construction: 

 

 

 

Enclosure:

 

ABS Plastic 

 

 

Lens: 

 

Polycarbonate

 

 

 

 

If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being adversely affected, thus ensuring that the 
type of protection is not compromised. 

 

“Aggressive substances” - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 

 

“Suitable precautions” - e.g. regular checks as part 
of routine inspections or establishing from the 
material’s data sheet that it is resistant to specific 
chemicals. 
 

 

The IS-mB1 beacon is CE marked for 

compliance with the European Explosive 

2014/34/EU and the European EMC 

Directive 2014/30/EU 

 

II 1G    Ex ia IIC T4 Ga (-40ºC <= Ta <= +60ºC) 

Reviews: