E2S GNExCP6C-PB Instruction Manual Download Page 4

Y

M/S 1

S

E

R

IE

S

-

+

M/S 1

-

+

8

7

6

5

4

3

2

1

R

B

Y

M/S 1

S

E

R

IE

S

E

O

L

-

+

M/S 1

-

+

8

7

6

5

4

3

2

1

R

B

Y

S

E

R

IE

S

M/S 1

E

O

L

-

+

M/S 1

-

+

8

7

6

5

4

3

2

1

R

B

3

4

+

-

3

4

+

-

DIODE

ZENER
DIODE

DEVICE POLARITY

+

2

1

+

2

1

DEVICE POLARITY

ZENER
DIODE

DIODE

-

-

2

3

4

+

-

+

DIODE

ZENER
DIODE

DEVICE POLARITY

2

3

4

+

-

+

2

3

4

+

-

2

3

4

+

-

DEVICE POLARITY

ZENER
DIODE

DIODE

-

2
+

3
+

4
-

5

EOL

2

S

E

R

IE

S

5
-

4
-

3
+

+

EOL

2
+

3
+

4
-

5
-

S

E

R

IE

S

1

S

E

R

IE

S

EOL

5
-

4
-

2
+

+

Series
Module [s]

EOL Module [e]

Product
Option [o]

GNEXCP6B-BG[s][t][l][e][m][d][v][o][x][u]-[v][e][s]

Product
Version [v]

LED Indicator [u]

Switch Type [s]

Terminals [t]

Y

M/S 1

E

O

L

-

+

M/S 1

-

+

8

7

6

5

4

3

2

1

R

B

GNExCP6B/C/D/E CALL POINTS

D.HOWGILL

2S

CODING UPDATE FOR CONFIG 3 AND 4

D.A.H - 21-02-2022

TYPE E ADDED. DUAL VERSION 

SCHEMATICS UPDATED. SHEET 3 ADDED

3

WWW.E2S.COM

C

LONDON W3 7QH

ACTON

MANSELL ROAD

IMPRESS HOUSE

EUROPEAN SAFETY SYSTEMS LTD

ACN0077

2

FOR LED DIAGRAMS. D.A.H - 28-08-2020

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

EUROPEAN SAFETY SYSTEMS LTD.

WRITTEN CONSENT.

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

LINEAR DIMENSIONAL TOLS

DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D154-06-051

R.N.POTTS

D.A.H - 17-11-2022

R.N.POTTS

07-02-20

OF

IF IN DOUBT, ASK - 

CALL POINT WIRING SCHEMATIC

NTS

1

6

07-02-20

07-02-20

GNExCP6B/C/D/E-BG/PB/PT MANUAL 

GEOMETRIC TOLERANCES TO ISO1101:1983

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

DRAWING TO BS8888:2000

DEVICE POLARITY ADDED. CONFIG 8 AND 12 ADDED (LED ONLY)

CONFIG 13 REMOVED, CONFIGS RE-NUMBERED 1 TO 24

4

warning signals

Circuit shown in Unoperated condition 

Unoperated condition
(Glass Intact / Standby Condition)

Ter(2,3) & -(4,5) open
Ter(2,3) & (6) closed

Operated condition
(Glass Broken / Button pushed in)

Ter(2,3) & -(4,5) closed
Ter(2,3) & (6) open

Circuit shown in Unoperated condition 

Unoperated condition
(Glass Intact / Standby Condition)

Ter(2,3) & -(4,5) open
Ter(2,3) & (6) closed

Operated condition
(Glass Broken / Button pushed in)

Ter(2,3) & -(4,5) closed
Ter(2,3) & (6) open

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Ter(2,3) & -(4,5) open
Ter(2,3) & (6) closed

Operated condition
(Glass Broken / Button pushed in)

Ter(2,3) & -(4,5) closed
Ter(2,3) & (6) open

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Ter(1,2) & -(4,5) M/S 1 open
Ter(1,2) & (6) M/S 1 closed

Operated condition
(Glass Broken / Button pushed in)

Ter(1,2) & -(4,5) M/S 1 closed
Ter(1,2) & (6) M/S 1 open

Module Device Codes

EOL

Series

Resistor

ExxxR

SxxxR

Diode

ED1

SD1

Zener Diode

ExxxZ

SxxxZ

LED

N/A

L or C

SINGLE MICROSWITCH | DEVICES

SINGLE SWITCH WITH EOL DEVICE

SINGLE SWITCH WITH SERIES DEVICE

SWITCH TYPE [s]

PRODUCT OPTION [o]

EOL MODULE [e]

SINGLE SWITCH WITH EOL DEVICE

CONFIG. 1

CONFIG. 2

SINGLE SWITCH WITH EOL & SERIES DEVICE

SWITCH TYPE [s]

PRODUCT OPTION [o]

MODULES [e][s]

SINGLE SWITCH WITH EOL & SERIES DEVICE

SWITCH TYPE [s]

PRODUCT OPTION [o]

MODULE [e][s]

CONFIG. 3

CONFIG. 4

Diagram

Sheet

Dual Switch Wiring Configurations

2,4,5,6

LED Indicator Wiring Configurations

3,4,6

Parallel Dual Switch Wiring Configurations

5, 6

[S]

[1]

[Exxxx]

SWITCH TYPE [s]

PRODUCT OPTION [o]

SERIES MODULE [s]

Single

Standard

EOL Device

[S]

[1]

[Sxxxx]

Single

Standard

Series Device

[S]

[1]

[Exxxx][Sxxxx]

Single

Standard

EOL + Series

[S]

[W]

[Exxxx][Sxxxx]

Single

Alternative Wiring

EOL + Series

SHEET 1

PRODUCTS:
GNExCP6B/C/D/E - BG
GNExCP6B/C/D/E - PB
GNExCP6B/C/D/E - PT

Summary of Contents for GNExCP6C-PB

Page 1: ...by SIRA and have been approved to the following standards EN60079 0 2018 IEC60079 0 2017 EN60079 1 2014 IEC60079 1 2014 EN60079 7 2015 IEC60079 7 2017 EN60079 18 2015 IEC60079 18 2014 EN60079 31 2014...

Page 2: ...ent Limitations The maximum allowable current is determined as the smallest value from the following scenarios 1 When both module resistor values are the same as or above the minimum range of values s...

Page 3: ...EC EN61508 which has been assessed and is considered suitable for use in low demand safety function Random Hardware Failures and Systematic Failures route 2H As an unvoted item i e hardware fault tole...

Page 4: ...DED CONFIG 8 AND 12 ADDED LED ONLY CONFIG 13 REMOVED CONFIGS RE NUMBERED 1 TO 24 4 warning signals Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2...

Page 5: ...cuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed Operated condition Glass Broken B...

Page 6: ...ng signals Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2 3 4 5 open Terminals 2 3 6 closed Operated condition Glass Broken Button pushed in Term...

Page 7: ...he LED current limiting resistor RL1 using LED option C In all other cases RL1 is included Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2 3 M S 1...

Page 8: ...S 1 M S 2 open Terminals 2 3 6 M S 1 M S 2 closed Operated condition Glass Broken Button pushed in Terminals 2 3 4 5 M S 1 M S 2 closed Terminals 2 3 6 M S 1 M S 2 open Circuit shown in Unoperated co...

Page 9: ...rated condition Glass Broken Button pushed in Terminals 3 4 5 6 M S 1 M S 2 closed Terminals 3 4 7 M S 1 M S 2 open Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Cond...

Page 10: ...surance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 681...

Page 11: ...and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evaluation Authorisation and Restriction of Chemicals REACH The product and all the componen...

Page 12: ...t GNExCP6A GNExCP6B GNExCP6C GNExCP6D GNExCP6E II 2G Ex db eb IIC T6 Gb 40 C Ta 70 C II 2D Ex tb IIIC T75 C Db 40 C Ta 70 C or II 2G Ex db eb mb IIC T4 Gb 40 C Ta 50 C II 2D Ex tb IIIC T80 C Db 40 C T...

Page 13: ...ity Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 On behalf of European Safety Systems Ltd I declare that on the date...

Reviews: