_______________________________________________________________________________________________________________________________
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D155-00-201-IS Issue 3 28-11-22 Sheet 5 of 5
1SIL 2 Reliability Data
Reliability and Functional safety IEC/EN61508 which has
been assessed and is considered suitable for use in low
demand safety function:
1. Random Hardware Failures and Architectural constraints
(route
2
H
).
2. As an unvoted item (i.e. hardware fault tolerance of 0) at
SIL 2.
The product was assessed against failure modes:
Failure respond to an input by lighting a beacon.
Spurious light output despite no input.
3.
When employing the device in a SIL2 compliant system
the user should ensure frequent or continuous automatic
monitoring of continuity.
Integrity in respect of failure to
function
SIL2
& SIL1
Total Failure rate
0.
48
pmh
“Hazardous” failure rate (revealed)
0
pmh
“Hazardous” failure rate (unrevealed)
0.
48
pmh
“Safe” failure rate (revealed)
0 pmh
“Safe” failure rate (unrevealed)
0
System type
B
Hardware Fault Tolerance
0
Diagnostic Coverage
>
60
%
PFD (hazardous failure)
2.1
x 10
-
3
Proof Test Interval
Up to 1 year
Summary of Contents for GNExB1X05