32 

745Hz @ 1Hz Intermittent 

  

1 1 1 1 1 0 

44 24  8 

33 

800Hz -  0.25sec on, 1 sec off 
Intermittent 

  

0 0 0 0 0 1 

53 24  8 

34 

800Hz @ 2Hz IMO code 3.a 
(High) Intermittent 

  

1 0 0 0 0 1 

56 24  8 

35 

1000Hz @ 1Hz Intermittent 

  

0 1 0 0 0 1 

44 24  8 

36 

2400Hz @ 1Hz Intermittent 

  

1 1 0 0 0 1 

21 24  8 

37 

2900Hz @ 5Hz Intermittent 

  

0 0 1 0 0 1 

53 24  8 

38 

363/518Hz @ 1Hz Alternating 

  

1 0 1 0 0 1 

1 8 19 

39 

450/500Hz @ 2Hz Alternating 

  

0 1 1 0 0 1 

1 8 19 

40 

554/440Hz @ 1Hz Alternating 

 

1 1 1 0 0 1 

44 24 19 

41 

554/440Hz @ 0.625Hz 
Alternating 

  

0 0 0 1 0 1 

1 8 19 

42 

561/760Hz @0.83Hz (50 
cycles/minute) Alternating 

  

1 0 0 1 0 1 

1 8 19 

43 

780/600Hz @ 0.96Hz  
Alternating 

  

0 1 0 1 0 1 

1 8 19 

44 

800/1000Hz @ 2Hz 
Alternating 

  

1 1 0 1 0 1 

5 24 19 

45 

970/800Hz @ 2Hz Alternating 

  

0 0 1 1 0 1 

1 8 19 

46 

800/1000Hz @ 0.875Hz 
Alternating 

  

1 0 1 1 0 1 

53 24 19 

47 

2400/2900Hz @ 2Hz 
Alternating 

  

0 1 1 1 0 1 

57 24 19 

48 

500/1200Hz  @ 0.3Hz 
Sweeping 

  

1 1 1 1 0 1 

44 24 12 

49 

560/1055Hz @ 0.18Hz 
Sweeping 

  

0 0 0 0 1 1 

44 

24 

12 

50 

560/1055Hz @ 3.3Hz 
Sweeping 

  

1 0 0 0 1 1 

44 

24 

12 

51 

600/1250Hz @ 0.125Hz 
Sweeping 

  

0 1 0 0 1 1 

44 

24 

12 

52 

660/1200Hz  @ 1Hz 
Sweeping 

  

1 1 0 0 1 1 

64 

24 

12 

53 

800/1000Hz @ 1Hz Sweeping 

  

0 0 1 0 1 1 

56 

24 

12 

54 

800/1000Hz @ 7Hz Sweeping 

  

1 0 1 0 1 1 

57 

24 

12 

55 

800/1000Hz @ 50Hz 
Sweeping 

  

0 1 1 0 1 1 

54 

24 

12 

56 

2400/2900Hz @ 7Hz 
Sweeping 

  

1 1 1 0 1 1 

57 

24 

12 

57 

2400/2900Hz @ 1Hz 
Sweeping 

  

0 0 0 1 1 1 

47 

24 

12 

58 

2400/2900Hz @ 50Hz 
Sweeping 

  

1 0 0 1 1 1 

54 

24 

12 

59 

2500/3000Hz @ 2Hz 
Sweeping 

  

0 1 0 1 1 1 

44 

24 

12 

60 

2500/3000Hz @ 7.7Hz 
Sweeping 

  

1 1 0 1 1 1 

44 

24 

12 

61 

800Hz Motor Siren 

  

0 0 1 1 1 1 

44 

24 

12 

62 

1200Hz Motor Siren 

  

1 0 1 1 1 1 

44 

24 

12 

63 

2400Hz Motor Siren 

  

0 1 1 1 1 1 

44 

24 

12 

64 

Simulated Bell  

  

1 1 1 1 1 1 

44 

21 

12 

 

745Hz 0.5s

0.5s

800Hz 0.25s

1s

800Hz 0.25s

0.25s

1000Hz 0.5s

0.5s

2400Hz 0.5s

0.5s

2900Hz 0.1s

0.1s

1250Hz

600Hz

8s

1450Hz 0.25s

0.69ms

1200Hz

500Hz

3.34s

1055Hz

560Hz

5.47s

1055Hz

560Hz

0.3s

1200Hz

660Hz

1s

1000Hz

800Hz

1s

1000Hz

800Hz

0.14s

1000Hz

800Hz

0.02s

2900Hz

2400Hz

0.14s

2900Hz

2400Hz

1s

2900Hz

2400Hz

0.02s

3000Hz

2500Hz

0.5s

3000Hz

2500Hz

0.13s

800Hz

1.6s

1200Hz

2s

2400Hz

1.7s

363Hz

518Hz

0.5s

0.5s

500Hz

0.25s

0.25s

450Hz

554Hz

0.5s

0.5s

440Hz

554Hz

0.8s

0.8s

440Hz

760Hz

0.6s

0.6s

561Hz

780Hz

0.52s

0.52s

600Hz

1000Hz

0.25s

0.25s

800Hz

970Hz

0.25s

0.25s

800Hz

2900Hz

0.25s

0.25s

2400Hz

1000Hz

0.57s

0.57s

800Hz

Summary of Contents for D2xC2LD2 Series

Page 1: ...om UL464 92 2dB A at 10 feet reverberation room Testing of synchronization requirements of UL1971 UL1638 CAN ULC S526 were conducted by UL using a total of 6 units connected to the same wire run Auto...

Page 2: ...e rating per UL50E NEMA250 4 4X 3R 13 To maintain the ingress protection rating the cable entries must be fitted with suitably rated certified cable entry and or blanking devices during installation 2...

Page 3: ...on this cable run The wire size and total length of the cable run determining the total resistance of this cable run The minimum output voltage supplied by the power supply The voltage drop and input...

Page 4: ...Simply connect the supply voltage to the L and N supply terminals see fig 3a b The Strobe is powered via factory installed wires connected to the sounder The wires connecting the alarm horn and strob...

Page 5: ...their supply input lines An end of line monitoring resistor can be connected across the ve and ve terminals If an end of line resistor is used it must have the following values 24V DC Alarm Horn and...

Page 6: ...ip Switch 1 ON 0 OFF Example shown 100000 Flashing 1Hz Default setting 13 Interchangeable Spare Parts The Beacon lens cover is interchangeable contact E2S Ltd for a replacement lens cover available in...

Page 7: ...out to the correct NFPA standards and guidelines 15 1 Horizontal Light Output Dispersion for wall mounting public mode 0 15 15 30 45 60 75 90 90 30 45 60 75 Fig 13 Horizontal dispersion angles for wal...

Page 8: ...sion for wall mounting public mode 75 60 45 30 15 0 90 Fig 14 Vertical dispersion angles for wall mounting Table 4 Vertical Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity...

Page 9: ...per UL 1971 UL1638 CAN ULC S526 at worst case min input voltage 15 4 On axis light output rating private mode Table 5 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Inte...

Page 10: ...z 47 4mA 47 4mA Flashing 1 5Hz 50 3mA 50 3mA Flashing 2Hz 51 1mA 51 1mA Flashing Double Strike 62 2mA 62 2mA Flashing Triple Strike 69 2mA 69 2mA D2xC2LD2AC115 115Vac 60Hz 115 120Vac 50 60Hz Steady Hi...

Page 11: ...0 208 740 4200 Document No D211 00 611 IS SC Issue E 02 03 2020 Sheet 11 of 13 17 Sound Directional Characteristics for Canadian Fire CAN ULC S525 Horizontal Axis Angle OSPL Angle OSPL Reference 90 10...

Page 12: ...n 0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal...

Page 13: ...1 44 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 44 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1...

Reviews: