E2S D1xL1-V070-D Instruction And Service Manual Download Page 3

_________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. D190-00-251-IS-SC     Issue:  4                        37-08-15               Sheet 3 of 3 

 

The cable connections are made into the terminal blocks on the 
PCB assembly located in the explosionproof  enclosure. See 
section  5  of this manual for access to the explosionproof 
enclosure. The 70V Line loudspeakers are fitted with a five way 
terminal block. Terminal A is common and one of the other 
terminals B, C, D or E should be selected depending on what 
output level is required (see table below). 
 

Terminals

 

D1xL2 (25W)

 

D1xL1 (15W)

 

A - B 

25W 

15W 

A - C 

12.5W 

7.5W 

A - D 

6W 

3W 

A - E 

2W 

1W 

 
A single wire with a cross sectional area of up to 2.5mm² / 
AWG14  can be connected to each terminal way or if an input 
and output wire is required two wires can be connected to each 
terminal way when crimped with a ferrule. If more than one wire 
is fitted into a terminal a ferrule should be used to secure the 
wires. When connecting wires to the terminals great care should 
be taken to dress the wire so that when the cover is inserted into 
the chamber the wires do not exert excess pressure on the 
terminal blocks. 

 
7)  Low Impedance Wiring 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 4 Low Impedance Terminals 

 
D1xL2 and D1xL1 8 ohm and 16 ohm low impedance 
loudspeakers have dual input terminals on the PCB  assembly 
for input and output wiring. A cable of up to 4.0mm² can be 
connected to each terminal. If DC line monitoring is used cut the 
link on the board (see Fig. 4). 
 

8)  Earthing 
 

The unit has both a primary internal and secondary  external 
earth fixing point. 
 
Internal earth connections should be made to the internal Earth 
terminal (see Fig. 3 and 4. It should be fitted to the internal earth 
point using a ring crimp terminal to secure the earth conductor. 
 
In addition, external earth connections can be made to the M5 
earth stud (see Fig. 2), using a ring crimp terminal to secure the 
earth conductor to the earth stud. The external earth crimp ring 
should be located between the two M5 plain washers provided 
and securely locked down with the M5 spring washer and M5 
nut. 
 
The earth conductor should be at least equal in size and rating 
to the incoming power conductors but at least a minimum of 
0.82mm

2

 / 18AWG in size. 

9)  End of Line DC Monitoring 
 

On D1xL2 and D1xL1 Loudspeakers, DC line monitoring can be 
used if required. Both the 70V Line units and the Low Impedance 
units have blocking capacitors fitted. It should be noted that each 
loudspeaker has a 1M ohm bleed resistor connected across the 
blocking capacitor and this should be taken into account when 
selecting the value of the end of line monitoring resistance. 
 
The end of line monitoring resistor can be connected across the 
terminals on the end of line unit. 
 
On 70V line units the end of line resistor used must have a 
minimum resistance value of 4k7 ohms and a minimum wattage 
of 2.5 watts 
 
On low impedance units the end of line resistor used must have 
a minimum resistance value of 2k ohms and a minimum wattage 
of 0.5 watts or a minimum resistance value of 500 ohms and a 
minimum wattage of 2 watts. On the low impedance units care 
must be taken with the polarity of the monitoring voltage. If an 
end of line resistor is fitted to a unit the links on the printed circuit 
boards of all loudspeakers in the line must be cut for the dc 
blocking capacitors to be in circuit in order to dc monitor the line 
(see Fig 4). 
 

10)  Maintenance, Repair and Overhaul 

 
Maintenance, repair and overhaul of the equipment should only 
be carried out by suitably qualified personnel in accordance with 
the current relevant standards and regulations. 
 
Units must not be opened while an explosive atmosphere is 
present. 
 
If opening the unit during maintenance operations a clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 
 
The threaded flamepath joints are not intended to be repaired. 

-    -   +   + 

DC Line 
Monitoring Link 

Internal Earth 
Terminal 