background image

__________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)208 740 4200 
Document No. D190-00-301-IS-SC     Issue:  8                        24-04-19               Sheet 8 of 8 

 

32 

745Hz @ 1Hz Intermittent 

  

1 1 1 1 1 0 

32 

24 

33 

800Hz -  0.25sec on, 1 sec off 
Intermittent 

  

0 0 0 0 0 1 

33 

24 

34 

800Hz @ 2Hz IMO code 3.a 
(High) Intermittent 

  

1 0 0 0 0 1 

34 

24 

35 

1000Hz @ 1Hz Intermittent 

  

0 1 0 0 0 1 

35 

24 

36 

2400Hz @ 1Hz Intermittent 

  

1 1 0 0 0 1 

36 

24 

37 

2900Hz @ 5Hz Intermittent 

  

0 0 1 0 0 1 

37 

24 

38 

363/518Hz @ 1Hz Alternating 

  

1 0 1 0 0 1 

38 

19 

39 

450/500Hz @ 2Hz Alternating 

  

0 1 1 0 0 1 

39 

19 

40 

554/440Hz @ 1Hz Alternating 

 

1 1 1 0 0 1 

40 

24 

19 

41 

554/440Hz @ 0.625Hz 
Alternating 

  

0 0 0 1 0 1 

41 

19 

42 

561/760Hz @0.83Hz (50 
cycles/minute) Alternating 

  

1 0 0 1 0 1 

42 

19 

43 

780/600Hz @ 0.96Hz  
Alternating 

  

0 1 0 1 0 1 

43 

19 

44 

800/1000Hz @ 2Hz 
Alternating 

  

1 1 0 1 0 1 

44 

24 

19 

45 

970/800Hz @ 2Hz Alternating 

  

0 0 1 1 0 1 

45 

19 

46 

800/1000Hz @ 0.875Hz 
Alternating 

  

1 0 1 1 0 1 

46 

24 

19 

47 

2400/2900Hz @ 2Hz 
Alternating 

  

0 1 1 1 0 1 

47 

24 

19 

48 

500/1200Hz  @ 0.3Hz 
Sweeping 

  

1 1 1 1 0 1 

48 

24 

12 

49 

560/1055Hz @ 0.18Hz 
Sweeping 

  

0 0 0 0 1 1 

49 

24 

12 

50 

560/1055Hz @ 3.3Hz 
Sweeping 

  

1 0 0 0 1 1 

50 

24 

12 

51 

600/1250Hz @ 0.125Hz 
Sweeping 

  

0 1 0 0 1 1 

51 

24 

12 

52 

660/1200Hz  @ 1Hz 
Sweeping 

  

1 1 0 0 1 1 

52 

24 

12 

53 

800/1000Hz @ 1Hz Sweeping 

  

0 0 1 0 1 1 

53 

24 

12 

54 

800/1000Hz @ 7Hz Sweeping 

  

1 0 1 0 1 1 

54 

24 

12 

55 

800/1000Hz @ 50Hz 
Sweeping 

  

0 1 1 0 1 1 

55 

24 

12 

56 

2400/2900Hz @ 7Hz 
Sweeping 

  

1 1 1 0 1 1 

56 

24 

12 

57 

2400/2900Hz @ 1Hz 
Sweeping 

  

0 0 0 1 1 1 

57 

24 

12 

58 

2400/2900Hz @ 50Hz 
Sweeping 

  

1 0 0 1 1 1 

58 

24 

12 

59 

2500/3000Hz @ 2Hz 
Sweeping 

  

0 1 0 1 1 1 

59 

24 

12 

60 

2500/3000Hz @ 7.7Hz 
Sweeping 

  

1 1 0 1 1 1 

60 

24 

12 

61 

800Hz Motor Siren 

  

0 0 1 1 1 1 

61 

24 

12 

62 

1200Hz Motor Siren 

  

1 0 1 1 1 1 

62 

24 

12 

63 

2400Hz Motor Siren 

  

0 1 1 1 1 1 

63 

24 

12 

64 

Simulated Bell  

  

1 1 1 1 1 1 

64 

21 

12 

 

800Hz 0.25s

0.25s

1000Hz

0.5s

0.5s

2400Hz

0.5s

0.5s

2900Hz

0.1s

0.1s

1250Hz

600Hz

8s

1450Hz 0.25s

0.69ms

1200Hz

500Hz

3.34s

1055Hz

560Hz

5.47s

1055Hz

560Hz

0.3s

1200Hz

660Hz

1s

1000Hz

800Hz

1s

1000Hz

800Hz

0.14s

1000Hz

800Hz

0.02s

2900Hz

2400Hz

0.14s

2900Hz

2400Hz

1s

2900Hz

2400Hz

0.02s

3000Hz

2500Hz

0.5s

3000Hz

2500Hz

0.13s

800Hz

1.6s

1200Hz

2s

2400Hz

1.7s

363Hz

518Hz

0.5s

0.5s

500Hz

0.25s

0.25s

450Hz

554Hz

0.5s

0.5s

440Hz

554Hz

0.8s

0.8s

440Hz

760Hz

0.6s

0.6s

561Hz

780Hz

0.52s

0.52s

600Hz

1000Hz

0.25s

0.25s

800Hz

970Hz

0.25s

0.25s

800Hz

2900Hz

0.25s

0.25s

2400Hz

1000Hz

0.57s

0.57s

800Hz

745Hz

0.5s

0.5s

800Hz 0.25s

1s

Summary of Contents for D1xC2 Series

Page 1: ...S DE 18 POUCES QUIPEMENT NE DOIT PAS TRE INSTALL AVEC LE KLAXON TOURN E VERS LE HAUT DE HORIZONTAL NE PAS OUVRIR UN PRESENCE D ATMOSPHERE EXPLOSIVE NE PAS OUVRIR ENERGIE DANGER POTENTIEL CHARGE LECTRO...

Page 2: ...h the following standards for hazardous locations EN60079 0 2018 IEC60079 0 ed 7 0 2017 EN60079 1 2014 IEC60079 1 ed 7 0 2014 The D1xC1X05DC024 Combined Alarm Horns are rated as follows Ex db IIC T4 G...

Page 3: ...0Vac 60Hz D1xC2X05 DC024 24Vdc 924 mA 323 mA 1247 mA 20 28Vdc 1477 mA 20Vdc D1xC2X05 AC115 115Vac 60Hz 268 mA 130 mA 398 mA 110 120Vac 50 60Hz 446 mA 110Vac 60Hz D1xC2X05 AC230 230Vac 50Hz 159 mA 79 m...

Page 4: ...ee 7mm fixing holes The enclosure provides IP66 protection and is suitable for installation in exterior locations providing it is positioned so that water cannot collect in the horn and the cable entr...

Page 5: ...s on first and second stages and which tones are available for the third and fourth stages dependent on the Stage 1 DIP switch setting 8 Stage Switching Polarity DC Units Only The D1xC2 and D1xC1 DC a...

Page 6: ...itch 1 alters stage 4 tone Fig 8 DC Terminals 11 Earthing The unit has both a primary internal and secondary external earth fixing point Internal earth connections should be made to the internal Earth...

Page 7: ...9 34 1 10 1000Hz 1s on 1s off x7 7s on 1s off IMO Code 1a 1 0 0 1 0 0 10 34 1 11 420Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 11 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO...

Page 8: ...0 1 48 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 49 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 50 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 51 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0...

Reviews: