E2S D1 B2X05 Series Instruction Manual Download Page 5

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)208 740 4200 
Document No. D191-00-201-IS           Issue 1         03-06-2019                         Sheet 5 of 8

 

 

252.3 [9.93in]

7.00 [0.28in]

45.0°

3/4" NPT SIDE ENTRY
2 OFF POSITIONS

MARKED *

M20x1.5 SIDE ENTRY
2 OFF POSITIONS
MARKED #

3/4" NPT BOTTOM ENTRY
FOR POLE MOUNTING
BEACON

2 OFF FEET SUPPLIED IN STOWED POSITION
SUITABLE FOR POLE OR BRACKET
MOUNTING BEACON
RETAINED BY 2 OFF M5 SCREWS PER FOOT

1

6

6

.0

 [6.5

4i

n]

8

3.0 

[3

.2

7in]

2 OFF FEET SUPPLIED IN STOWED POSITION
SUITABLE FOR POLE OR BRACKET

MOUNTING BEACON

RETAINED BY 2 OFF M5 SCREWS PER FOOT

BASE CONFIGURED WITH
FEET SET OUT FOR SURFACE MOUNTING
BEACON

Ø9.0 [Ø0.36i

n]

It is important that a suitable power supply is used to run the 
equipment.  The  power  supply  selected  must  have  the 
necessary  capacity  to  provide  the  input  current  to  all  the 
units. 

 

The  input  current  will  vary  according  to  the  voltage  input 
level.  
 

3)  Special Conditions of Use 

 
The  enclosure  coating  is  non-conductive  and  may  generate 
an  ignition-capable  level  of  electrostatic  charges  under 
certain  extreme  conditions.  The  user  should  ensure  that  the 
equipment  is  not  installed  in  a  location  where  it  may  be 
subjected  to  external  conditions  (such  as  high  pressure 
steam)  which  might  cause  a  buildup  of  electrostatic  charges 
on  non-conducting  surfaces.  Additionally,  cleaning  of  the 
equipment should be done only with a damp cloth. 
 

Flame Path Positions 

 
 
 
 
 

 
 
 
 
 

 
 
4)  Installation 

 
There are no restrictions on unit orientation. 
 
The junction box must only be installed by suitably qualified 
personnel in accordance with the latest issues of the relevant 
standards: 
 
EN60079-14 / IEC60079-14: Explosive atmospheres - 
Electrical installations design, selection and erection 
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres - 
Classification of areas. Explosive gas atmospheres 
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres - 
Classification of areas. Explosive dust atmospheres 
 
The  installation of  the units must also be in accordance  with 
any  local  codes  that  may  apply  and  should  only  be  carried 
out  by  a  competent  electrical  engineer  who  has  the 
necessary training. 
 

4.1 Safe Installation Requirements 
 

To  maintain  the  ingress  protection  rating  and  mode  of 
protection,  the  cable  entries  must  be  fitted  with  suitably 
certified  cable  entry  and/or  blanking  devices  during 
installation.  If  conduit  is  used  for  installation,  seal  conduit 
within 18 inches from the enclosure. 
 
If  entries  are  fitted  with  adaptors  they  must  be  suitably 
certified  for  the  application.  Fitting  of  blanking  elements  into 
adaptors is not permitted. 
Check that the ‘O’ ring seal is in place before replacing the 
explosionproof cover. 
 
Lens guard must be fitted for Class Division installations. 

 

5)  Location and Mounting 

 

The  location of  the  beacon  should be  made  with  due  regard 
to  the  area  over  which  the  warning signal  must  be  visible.  It 
should  only  be  fixed  to  services  that  can  carry  the  weight  of 
the unit. 
 
The  D1xB2X  beacon  can  be  mounted  using  one  of  three 
methods. 
 
1.  The beacon can be surface mounted by removing, 

rotating and reinstalling the stowed mounting lugs. These 
are suitable for 6mm diameter fixings. 
 
a.   Remove 2 x M5 fasteners per 

 mounting lug 
 

b.  Reverse and rotate lug and 

reseat onto enclosure 
 

c. 

Secure lug using the 2 x M5 
Fasteners 

             

 

2.  Alternatively  the  beacon  can  be  conduit  mounted  using 

the ¾”NPT entry on the base of the unit. 
 

3.  Additionally,  the  beacon  can  be  mounted  using  the 

ratchet  adjustable  stainless-steel  wall  bracket  assembly. 
This  is  available  as  an  accessory 

–  part  code:  SP77-

0001. 

 
 
 
 
 
 
 
 
 
 

Fig. 1 Fixing Location for Beacon 

 

6)  Access to the Enclosure

 

 

 

 

 

 

In order to connect the electrical supply cables to the beacon, 
it is necessary to open the explosion proof enclosure. Loosen 
the locking grub screw in the cover and then remove the 
glass dome cover assembly to gain access to the chamber. 
This can be achieved by unscrewing the glass dome cover, 
taking extreme care not to damage the threads when doing 
so.  
 
 
 
 
 

Warning 

– High voltage may be present, 

risk of electric shock. DO NOT open when 
energised, disconnect power before 
opening. 

Warning 

 

Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 

Flame Path internal thread on 
base shown hatched 

Cemented Joint 
between glass 
dome and metal 
casting on lid 
shown hatched 

Flame Path 
external thread 
on lid shown 
hatched 

Summary of Contents for D1 B2X05 Series

Page 1: ...NT AVOIR UN RACCORD D TANCH IT RACCORD MOINS DE 18 POUCES DE L ENFERMEMENT POUR SUBS QUENT LES CONDUITES DE CONDUIT LA DISTANCE ENTRE LA SURFACE DE LA MASSE DE REMPLISSAGE AU PLUS PR S DE L ENVELOPPE...

Page 2: ...ABCD T4A Ta 55 C to 55 C Class II Div 1 Group EFG T4 Ta 55 C to 40 C Class III Div 1 Ta 55 C to 40 C The D1xB2X21DC024 D1xB2X21DC048 Xenon Beacons are rated as follows Class I Div 1 Group ABCD T3B Ta...

Page 3: ...Beacons are rated as follows Ex db IIC T3 Ta 55 C to 80 C Ex db IIC T4 Ta 55 C to 65 C Ex tb IIIC T132 C Ta 55 C to 80 C The D1xB2X15AC115 D1xB2X15AC230 Xenon Beacons are rated as follows Ex db IIC T...

Page 4: ...ent Dust Groupings Group IIIA Combustible Flyings Group IIIB Non conductive Dust Group IIIC Conductive Dust Maximum Surface Temperature for Dust Applications 104 C D1xB2X05DC 116 C D1xB2X05AC 135 c D1...

Page 5: ...codes that may apply and should only be carried out by a competent electrical engineer who has the necessary training 4 1 Safe Installation Requirements To maintain the ingress protection rating and...

Page 6: ...aling washer must be fitted under the cable glands or blanking plugs For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in explosive gas atmos...

Page 7: ...500 Ohms Minimum Power 2 0W The resistor must be connected directly across the ve and ve terminals as shown in the following drawing Form the resistor legs as shown in Fig 7a fit the resistor across...

Page 8: ...new lens cover Fig 10 Replacement of beacon lens cover Fit the wire guard back onto the housing over the new lens cover aligning the fixing holes of the guard lens cover and housing Refit the fixings...

Reviews: