INSTRUCTION MANUAL
BExS120D & BExS120D-R
Alarm Horn Sounder
ATEx/IECEx & UKEx Gas & Dust
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D210-00-011-IS
Issue 7
12-09-2022
Sheet 1 of 6
BExS120D
BExS120D-R
1. Product Table
Unit Type Code
Nominal
Input Voltage
Nominal
Input Current
Max I/P Voltage
Sound
Pressure Level
dB(A)
Max*
Nom
.†
BExS120DDC012 /
BExS120DDC012-R
12Vdc
850mA
15V
Flare:
123dB(A)
Radial:
115dB(A)
Flare:
117dB(A)
Radial:
110dB(A)
BExS120DDC024 /
BExS120DDC024-R
24Vdc
800mA
30V
BExS120DDC048 /
BExS120DDC048-R
48Vdc
420mA
60V
BExS120DAC115 /
BExS120DAC115-R
115Vac
180mA
126V
BExS120DAC230 /
BExS120DAC230-R
230Vac
90mA
253V
*Max = Tone 4
†
Nom. = Tone 44
The table shows the input current taken by the various sounders.
The current levels shown above are for the 440Hz Continuous tone @ nominal input voltage.
Nominal current at nominal voltage.
Table 1: Electrical Ratings.
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various sounders and shows the maximum voltage at which the sounders can
be operated:
The input current will vary according to the voltage input level and the frequency of the tone selected.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C