The following table shows the range of loudspeakers:- 

 

Unit Type 

Input  

 

Wattage   

Max. 

 

 

 

 

 

 

I/P Volts

 

 
BExL25E  

100V Line 

25W 

 

100V 

BExL25E  

8 ohm 

 

25W 

 

14.14V 

BExL25E  

16 ohm   

25W 

 

20V 

 
BExL15E  

100V Line 

15W 

 

100V 

BExL15E  

8 ohm 

 

15W 

 

10.95V 

BExL15E  

16 ohm   

15W 

 

15.49V 

 

The  above table  also shows the maximum  AC signal  voltages 
at which the loudspeakers can be operated. 
 
The  current  levels  taken by  the  each loudspeaker  will  depend 
on  which  output  tapping has been selected  (see  section  14 of 
this instruction manual). BExL25E 100V Line units have output 
levels of 25W ,  12.5W, 6W  and  2W, BExL15E  100V Line  units 
have output levels of 15W, 7.5W , 3W  and 1W . 
 

11) 

  Cable Selection 

 

W hen selecting the cable size  consideration  must  be  given to 
the  current that each  unit  draws, the  number  of  loudspeakers 
on the line and the length of the cable runs. 
 
SAFETY  WARNING:  If  the  loudspeakers  are  used  at  high 
ambient  temperatures,  i.e.  over  +40ºC,  then  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 
resisting  cables  must  be  used,  with  a  rated  service 
temperature of at least 95ºC. 
 

12) 

  Earthing

 

 

All  loudspeakers  must  be  connected  to  a  good  quality  earth. 
The  units  are  provided  with  internal  and  external  earthing  
terminals  which  are  both  located  on  the  terminal  chamber 
section of the unit (see figures 2 and 3).  
 
W hen using the external earth terminal a cable crimp lug must 
be used.  The cable lug should be located between the two M5  
stainless  steel  flat  washers.  The  M5  stainless  steel  spring 
washer  must  be  fixed  between  the  outer  flat  washer  and  the  
M5  stainless  steel  nut  to  ensure  that  the  cable  lug is secured 
against loosening and twisting.  
 
The  internal  earth  bonding  wires  ensure  that  a  good  quality 
earth  is  maintained between the  flameproof  chamber  casting, 
the terminal section casting and the terminal cover casting. 
 

13) 

  Cable Glands

 

 

The  BExL25E  and  BExL15E  loudspeakers  have  dual  cable 
gland entries which have an M20 x1.5 entry thread as standard  
or a  PG13.5  thread as  a  special. Only  cable  glands  approved 
for Ex ‘e’ applications or better (i.e. Ex ‘d’ applications) can be 
used.  They  must  be  suitable for  the  type  of  cable  to  be  used 
and  also  meet  the  requirements  of  the  Ex  equipment 
installation standard BS EN 60079-14: 1997. 
 
SAFETY  WARNING:  If  the  loudspeakers  are  used  at  high 
ambient  temperatures,  i.e.  over  +40ºC,  then  the  cable  entry 
temperature  may  exceed  +70ºC  and  therefore  suitable  heat 

resisting  cable  glands  must  be  used,  with  a  rated  service 
temperature of at least 95ºC. 
 
If  a  high  IP  (Ingress  Protection)    rating  is  required  then  a 
suitable sealing washer must be fitted under the cable gland.  
 
W hen  only  one  cable  entry  is  used  the  other  one  must  be 
closed  with  an  Ex  ‘e’  blanking  plug,  which  must  be  suitably 
approved for the installation requirements.  
 

14) 

  Cable Connections 

 

The  cable  connections  are  made  into  an  EEx  e  II  approved 
twelve  way  terminal  block  (six  way  on  low  impedance  units) 
which  is  located  in  the  Increased  Safety  Area  terminal 
chamber  (see  figure  3).  See  section  9  of  this  manual  for 
access  to  the  terminal  chamber. W hen  wiring  into  Increased 
Safety  Area  terminal  enclosures,  you  are  only  permitted  to 
connect  one  wire  into  each  way  on  the  terminal  block. 
Therefore  in  order  that  loudspeakers  can  be  connected  in  a 
parallel  line,  the  terminal  block  is  fitted  with  approved 
connecting  combs  so  that  each  electrical  connection  has  two 
terminals  in parallel. Terminal  No’s.  1 and 12  (1  and 6 on  low 
impedance units) must not be used on any units. Cables with a 
cross-sectional  area  of  up  to  4mm²  can  be  connected  to  the 
terminal  block.  Cables  that  have  a  small  cross-sectional  area 
should be fitted with crimp ferules. 
 
The  low  impedance  loudspeakers  are  fitted  with  two  pairs  of 
terminals 2-3 and 4-5. 
 
The  100V  Line  loudspeakers  are  fitted  with  five  pairs  of 
terminals.  Terminals 10-11  which are  the  common  and one of 
the other four pairs of terminals 8-9, 6 -7, 4-5 or 2-3  should be 
selected  depending on  what  output  level  is  required  (see  the 
following table). 

 

 

BExL25E (25W)         BExL15E (15W) 

Terminals

 

100V Line 

      100V Line 

 

10-11  to  8-9 

      25W  

 

15W 

10-11  to  6-7 

     12.5W 

 

7.5W  

10-11  to  4-5 

      6W    

 

3W 

10-11  to  2-3 

      2W    

 

1W 

 

15) 

  End of Line DC Monitoring 

 

 

On  BExL25E  and  BExL15E  loudspeakers,  dc  line  monitoring 
can be used if required. Both the 100V Line units and the Low 
Impedance units  have  a  blocking capacitor  fitted. It should be 
noted  that  each  loudspeaker  has  a  1M  ohm  bleed  resistor 
connected  across  the  blocking  capacitor  and  this  should  be 
taken  into  account  when selecting  the value  of the end of  line 
monitoring resistance. 
 
The  end  of  line  monitoring  resistor  can  be  connected  to  the 
end  of  line  unit. 

Note  the  monitoring  resistor  M UST   be 

connected to  the  terminals in  the  flameproof enclosure, it 
M UST NOT be connected to the terminals in the Increased 
Safety termination enclosure (see section 8 of this manual 
for  access  to  the  flameproof  enclosure). 

Figures  4  and  5 

show  the  terminals  in  the  flameproof  enclosures for  the  100V 
Line  and  low  impedance  units  respectively.

 

On  the  low 

impedance  units  care  must  be  taken  with  the  polarity  of  the 
monitoring voltage. 
 

Cable Entries 