European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

www.e2s.com

 

Tel: +44 (0)208 743 8880

Document No. D210-00-601-IS

 

Issue 8

 

12-09-2022

Sheet 2 of 7

 

3.  Marking & Rating Information 

The  BExCS110-05D-P  &  BExCS110-05D-R-P  Alarm  Horns  comply 
with the following standards for hazardous locations:  
  

3.1 ATEX / IECEx & UKEx Ratings

 

 

Standards

EN60079-0:2018/IEC60079-0:2017 

(ed.7): 

Explosive 

Atmospheres - Equipment General Requirements. 
EN60079-1:2014/IEC60079-1:2014 

(ed.7): 

Explosive 

Atmospheres - Equipment Protection by Flameproof Enclosures 
“d”. 
EN60079-31:2014/IEC60079-31:2013 

(ed.2): 

Explosive 

Atmospheres - Equipment Dust Ignition Protection by enclosure 
“t”. 

Model No: 

Rating 

BExCS110-05D-P 
/  BExCS110-05D-
R-P 

Ex db IIC T5 Gb Ta. -50°C to +40°C  
Ex db IIB T4 Gb Ta. -50°C to +70°C 
Ex tb IIIC T110°C Db Ta. -50°C to +55°C 
Ex tb IIIC T125°C Db Ta. -50°C to +70°C 

See Product table for electrical ratings of each unit model 

 

Certificate No.    

KEMA  01ATEX2223X 
IECEx KEM 10.0025X 
UL22UKEX2639X 

Epsilon x 
Equipment Group 
and Category: 

 

II 2G 
II 2D

 

CE Marking and 
Notified Body No. 

2813 

UKCA Marking and 
Approval Body No. 
 

 

0518 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.  Zones, Gas Group, Category and 

Temperature Classification 

The units can be installed in locations with the following conditions: 
 

Area Classification Gas 

Zone 1 

Explosive gas air mixture likely to occur in normal 
operation.

Zone 2 

Explosive gas air mixture not likely to occur in 
normal operation, and if it does, it will only exist for 
a short time. 

Gas Groupings 

Group IIA

Propane

Group IIB

Ethylene

Temperature Classification for Gas Applications

T1

450

o

T2

300

o

C

T3

200

o

C

T4

135

o

C

T5

100

o

C (Up to 40°C Ambient) 

Area Classification Dust 

Zone 21 

Explosive dust air mixture likely to occur in normal 
operation.

Zone 22 

Explosive dust air mixture not likely to occur in 
normal operation, and if it does, it will only exist for 
a short time. 

Dust Groupings 

Group IIIA

Combustible Dusts 

Group IIIB

Non-Conductive Dusts 

Group IIIC

Conductive Dusts 

Equipment Category 

2G, 2D

Equipment Protection Level 

Gb, Db,

Maximum Surface Temperature for Dust Applications

110°C at +55°C  

125°C at +70°C  

Ambient Temperature Range

-50°C to +70°C Gas Groups IIA and IIB 

-50°C to +70°C Dust Groups IIIA, IIIB and IIIC 

IP Rating 

IP66/67 to EN/IEC60529 and

IP6X to EN/IEC60079-0, EN/IEC60079-31 

The  unit  must  only  be  installed  by  suitably  qualified  personnel  in 
accordance with the latest issues of the relevant standards: 
  
EN60079-14  /  IEC60079-14:  Explosive  atmospheres  -  Electrical 
installations design, selection and erection 
EN60079-10-1  /  IEC60079-10-1:  Explosive  atmospheres  - 
Classification of areas. Explosive gas atmospheres 
EN60079-10-2  /  IEC60079-10-2:  Explosive  atmospheres  - 
Classification of areas. Explosive dust atmospheres 
 
The installation of the unit must also be in accordance with any local 
codes that may apply and should only be carried out by a competent 
electrical engineer who has the necessary training.

 

 

Summary of Contents for BExCS110-05D-P

Page 1: ...05DPAC230 BExCS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440Hz Continuous to...

Page 2: ...air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Application...

Page 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Page 4: ...section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal ear...

Page 5: ...m power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor must be connected directly across the ve and ve terminals as shown in the following...

Page 6: ...sounder on stage one simply connect the supply voltage to the normal supply terminals ve and ve for DC units L and N for AC units Refer to wiring schematics D210 06 601 DC or D210 06 605 AC Default To...

Page 7: ...Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive at...

Page 8: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Page 9: ...Page left Intentionally blank...

Page 10: ...ER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Set to negative switching default Stage 1 Apply Power to Stage 1 ve Stage 1 ve Two...

Page 11: ...RFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 605 R S RAIT B...

Page 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Page 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Page 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Page 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Page 16: ...Page left Intentionally blank...

Reviews: