E2S BExCP3A-BG Instruction Manual Download Page 15

 

 

 

 

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com   DC-093_Issue_A (BExCP3) - Page 2 of 2 - QAF_252_Issue_5

 

 

 

 

Martin Streetz 

Document No.: 

DC-093_Issue_A 

Quality Assurance Manager 

Date and Place of Issue: 

London, 24/02/2022 

UKCA Declaration of Conformity 

Other Standards and Regulations 

EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66 

Construction and design requirements according to EN54-11:2001 clause 4.7 – BExCP3A-BG / B-BG / C-BG / D-BG only (fitted with burning house symbol shown in 
figure 3a and no lift flap) 

 

On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment 
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards. 

 
This Declaration is issued under the sole responsibility of the manufacturer.

 

 

Summary of Contents for BExCP3A-BG

Page 1: ...ion certificate issued by SIRA and have been approved to the following standards EN60079 0 2018 IEC60079 0 2017 EN60079 1 2014 IEC60079 1 2014 EN60079 7 2015 IEC60079 7 2017 EN60079 18 2015 IEC60079 1...

Page 2: ...t is determined as the smallest value from the following scenarios 1 When both module resistor values are the same as or above the minimum range of values shown in table 1 the current is not further l...

Page 3: ...re fault tolerance of 0 at SIL 2 The product was assessed against failure modes Failure to close a contact when the call point is struck with specified force Failure to open a contact when the call po...

Page 4: ...CP3A PB BExCP3B PB BExCP3C PB BExCP3D PB BExCP3E PB Acionador Manual de Alarme com Bot o Pulsador de Rearme Rotativo por Chave BExCP3A PT BExCP3B PT BExCP3C PT BExCP3D PT BExCP3E PT Certificado Sira 0...

Page 5: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Page 6: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Page 7: ...24V mostrada consulte as observa es para obter informa es sobre as altera es necess rias para outras variantes de tens o Tens o nominal 24V mostrada consulte as observa es para obter informa es sobre...

Page 8: ...os s o certificados como Ex db eb IIC T6 Gb e como tais podem ser utilizados nas Zonas 1 e 2 com gases e vapores inflam veis e com os grupos de aparelhos IIA IIB IIC e classes de temperatura T1 T2 T3...

Page 9: ...e IIIC Os equipamentos s o certificados somente para uso em temperaturas entre 40o C e 65o C e n o dever o ser utilizados fora desta faixa Acionador Manual de Alarme Quebra Vidro BExCP3D BG Acionador...

Page 10: ...ser realizado somente por pessoal adequadamente treinado em conformidade com o c digo de pr tica aplic vel ex IEC 60079 19 EN 60079 19 7 A certifica o destes equipamentos se deve a estes materiais ut...

Page 11: ...CALL POINT BExCP3B C D PB PUSH BUTTON MANUAL CALL POINT BExCP3B C D PT TOOL RESET MANUAL CALL POINT IS CP4B BG BREAK GLASS MANUAL CALL POINT IS CP4B PB PUSH BUTTON MANUAL CALL POINT IS CP4B PT TOOL R...

Page 12: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment BExCP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db...

Page 13: ...y high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11...

Page 14: ...CP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db eb IIC T6 Gb 40 C Ta 70 C II 2D Ex tb IIIC T75 C Db 40 C Ta 70 C or II 2G Ex db eb mb IIC T4 Gb 40 C Ta 50 C II 2D Ex tb IIIC T60 C Db 40 C Ta 50 C or...

Page 15: ...d by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11 2001 clause 4 7 BExCP3A BG B BG C BG D BG only fitted with burning house symbol shown in figure 3...

Reviews: