When  using  the  internal  earth  terminal  ensure  that  the 

stainless steel M4 flat washer is between the incoming earth 
wire and the enclosure. 

 
When using the external earth terminal a cable crimp lug 
must be used.  The cable lug should be located between the 

two M5 stainless steel flat washers. The M5 stainless steel 
spring washer must be fixed between the outer flat washer 

and the M5 stainless steel nut to ensure that the cable lug is 
secured against loosening and twisting.  

 
The  internal  earth  bonding  wire  ensures  that  a  good quality 

earth is maintained between the flameproof chamber casting 
and the flameproof cover casting. 
 

12) 

 Cable Glands

 

 

The  BExH120D  Hootronic  sounder  has  dual  cable  gland 
entries  which  have  an  M20  x1.5  entry  thread  as  standard. 

Only  cable  glands  approved  for  Ex  ‘d’  applications  can  be 
used, which must be suitable for the type of cable being used 

and  also  meet  the  requirements  of  the  Ex  ‘d’  flameproof 
installation standard  EN60079-14:2008 / IEC60079-14:2007. 

 
SAFETY  WARNING:  If  the  BExH120D  sounder  is  used  at 

high  ambient  temperatures,  i.e.  over  +40ºC,  then  the  cable 
entry temperature may 70ºC and therefore suitable 
heat resisting cable glands must be used, with a rated service 

temperature of at least 110ºC. 
 

If  a  high  IP  (Ingress  Protection)  rating  is  required  then  a 
suitable sealing washer must be fitted under the cable gland.  

 
When  only  one  cable  entry  is  used  the  other  one  must  be 
closed with an Ex ‘d’ flameproof blanking plug, which must be 

suitably approved for the installation requirements.  
 

13) 

 Cable Connections 

 

The cable connections are made into the terminal blocks on 
the  electronic  pcb  assembly  located  in  the  flameproof 

enclosure.  See  section  8  of  this  manual  for  access  to  the 
flameproof  enclosure.  On  the  AC  units  a  two-way  terminal 

block is provided for the live and neutral mains supply wires 
and a four way terminal block is provided for linking the Stop 

and the second and third stages, (see figure 5). On the DC 
units  a  five  way  terminal  block  is  provided  for  +ve  and  –ve 
supply input and second and third stage and the Stop modes 

of operation, (see figure 4). 
 

 

 -  

 2

   3

  S

top

1

2
3

S2

S3

Stop +

ve

-ve

 

 

 
A single wire with a cross sectional area of up to 4mm² can 

be connected to each terminal way or if an input  and output 
wire is required two 2.5mm² wires can be connected to each 

terminal  way.  When  connecting  wires  to  the  terminals  great 
care should be taken to dress the wire so that when the cover 
is  inserted  into  the  chamber  the  wires  do  not  exert  excess 

pressure on the terminal blocks. This is particularly important 
when  using  cables  with  large  cross sectional  areas such  as 

2.5mm² and above. 
 

 

N

  L

-   

2   

3  S

top

1
2
3

 

 

14) 

 Sound Selection

 

 

The BExH120D Hootronic sounder has 5 different traditional 
sounds  that  can  be  selected  for  the  first  stage  alarm.  The 
sounders  can  then  be  switched  to  sound  second  and  third 

stage alarm sounds. The sounds are selected by pin headers 
on  the  pcb  for  both  DC  and  AC  units.  The  sound  table  on 

page four  shows  the  pin  header  positions  for  the  5  sounds 
and  which  sounds  are  available  for  the  second  and  third 

stages.  
 

The BExH120D Hootronic sounder has the facility to replicate 
the “tail off” traditionally associated with these sounds when 
generated  by  electro-mechanical  devices.  The  switching  is 

achieved using the “Stop” terminal (see section 15). 
 

15) 

Stop and 2nd & 3rd Stage Alarm Sound Selection

 

 

The operation of the second and third stages is different for 

DC and AC units. 
 

DC Units Second and Third Stage Sound Selection 
 

The BExH120D Hootronic DC sounder has the facility to use 
either  +ve  or  –ve  switching  to  change  the  sound  to  the 
second and third stages. For –ve switching connect the two 

headers on the pcb to the left-hand (marked –ve) and centre 
pins. For +ve switching connect the headers to the right hand 

(ve) and the centre pins. To change to the second 
stage  sound,  connect  either  a  -ve  or  +ve  supply  line  to 

terminal  S2,  depending  on  which  switching  mode  is  being 
used  while  maintaining  the  dc  supply  to  the  +ve  and  –ve 

terminals. Similarly for the third stage sound, connect a -ve or 
+ve supply line to terminal S3. The supply to the S3 terminal 
will automatically override a supply to the S2 terminal. 

 

 

 
 

Figure 4 

Figure 5 

BExH120D  DC Sounder 

BExH120D  AC Sounder 

Volume Control 

DC Terminals 

Sound Headers 

Volume Control 

Stage Terminals 

AC Terminals 

Stage Headers 

Stage Headers 