background image

 

 

 

TRIM-LINE  Boltless Shelving 

                                                                                                                                                                                                                  

Assembly Instructions

 

 

 

 

 

 

ALLOWABLE SPACING BETWEEN FRAME CONNECTORS

 

 

  

NUMBERS OF POST CONNECTORS REQUIRED 

 

 

Light to Medium Loads 

up to 3,000lb (1,361kg) 

or up to 24" (610mm) in Depth

 

Height of Post 

Light to Medium Loads 

up to 3,000lb (1,361kg) or 

up to 24" (610mm) in Depth

 

Inches 

Metric 

Two Hook 

Three Hook 

24" to 36" 
48" to 84" 

96" to 108" 

120" to 144" 

610mm to 914mm 

1219mm to 2134mm 
2438mm to 2743mm 
3048mm to 3658mm 




Dimension A 

Not to Exceed 

12" (305mm) 

20" (508mm) 

Dimension B 

Not to Exceed 

36" (914mm) 

48" (1219mm) 

 

 

 

 

 

 

 

 

Two Hook Connectors 

 

 

ALLOWABLE SPACING BETWEEN FRAME CONNECTORS

 

 

  

NUMBERS OF POST CONNECTORS REQUIRED

 

 

 

Heavy Loads over 3,000lb (1,361kg) 
to 7,000lb (3,175kg) or 30" (762mm) 

and 36" (914mm) in Depth

 

Height of Post 

Heavy Loads over 3,000lb (1,361kg) 

to 7,000lb (3,175kg) or 30" (762mm)   

and 36" (914mm) in Depth

 

Inches 

Metric 

Two Hook

 

Three Hook

 

24" to 36" 
48" to 84" 

96" to 108" 

120" to 144" 

610mm to 914mm 

1219mm to 2134mm 
2438mm to 2743mm 
3048mm to 3658mm

 




6

 

Dimension A 

Not to Exceed

 

Bottom

 

6" (152mm)

 

Dimension B 

Not to Exceed

 

24" (610mm)

 

30" (762mm)

 

 

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 
IMPORTANT NOTES: 

 

  Post Connector requirements are for static loading only; no shocks, vibrations, seismic, mobile or other special conditions are considered. 

  Always lock all post connectors on both sides to the posts that make up the shelving end frame. Refer to the assembly instructions guide for typical placement. 

  Be sure the post connectors are tapped down completely so the locking tab can be engaged before twisting and locking tab as per drawing. It is best to use a chainsaw wrench 

     but a 3/8" screwdriver can also be used. 

  Not locking the post connectors can lead to a dangerous situation and the shelving could collapse. 

  Please contact your representative or the factory direct for help on design, seismic and mobile aisle, 

CDN./ U.S. 1 888 397 4353  

 U.K. 01993 779494

.

 

Three Hook Connectors 

 

 

LAYOUT INFORMATION - CREEPAGE

 

When designing shelving layout, allow for an additional 1 1/2" 
(38.1 mm) creepage for each end frame in the row and 1" (25.4 mm) 
creepage in depth for each end frame. 

 

 E-Z-Rect Manufacturing Ltd. TL Revised October 2019

 

POST CONNECTOR TABS 

MUST BE

 

LOCKED IN PLACE FOR SAFETY, TYP. 

USE THREE MIDDLE POST 
CONNECTOR SLOTS, TYP. 

POST CONNECTOR TABS 

MUST BE

 

LOCKED IN PLACE FOR SAFETY, TYP. 

USE THREE MIDDLE POST 
CONNECTOR SLOTS, TYP. 

      POST                                    POST                                    POST                                   POST                                    POST                                   POST                                   POST 
60" [1524mm]                       72" [1829mm]                       84" [2134mm]                       96" [2438mm]                     108" [2743mm]                     120" [3048mm]                     144" [3658mm] 

      POST                                    POST                                    POST                                   POST                                    POST                                   POST                                   POST 
60" [1524mm]                       72" [1829mm]                       84" [2134mm]                       96" [2438mm]                      108" [2743mm]                     120" [3048mm]                     144" [3658mm] 

Reviews: