![E.T. Systems E PAD User Manual Download Page 5](http://html.mh-extra.com/html/e-t-systems/e-pad/e-pad_user-manual_519277005.webp)
5
Ver.201105.007
Default the Keypad to factory default settings:
NB! All factory settings and codes will be restored to the default values and all previously programmed user codes will
be erased.
Power the E Pad down.
Open the unit to access PCB
Place jumper in the “system restore” position.
Power the E Pad up.
At continuous tone, remove and replace jumper in original position.
Replace and secure cover.
LED Statuses
Power LED
Green Lock Relay
LED
Amber Aux Relay
LED
Red =
Normal
mode
On = Relay active
On = Relay active
Yellow =
Programming
mode
Off = Standby
Off = Standby
Flashing = Door
alarm memory.
Enter user code
twice to clear.