Check and Adjust the Circular Level 

1. Adjust  the  leveling  screws  to  center  the  bubble  in  the 

circular level. 

2. Turn the instrument 180°, and follow the following steps if 

the bubble shifts. 

3. Adjust the leveling screws, and move the bubble one half 

of the shift to the center of the circular level. 

4. Adjust  the  adjusting  screws  of  the  circular  level  with  the 

hexagonal wrench, and make the bubble in the center.  

5. Repeat the above steps until the bubble does not shift when 

the instrument turns to any direction. 

 

 