Audio Sync
• The displayed tempo on the
multiclock
might be subject to
roundoff deviation on the last decimal place. This does not
affect syncronization at all.
• You can also use a percussive sound at 24 ppq or an analog LFO
as the master clock. Please make sure that the positive pulse
width is at least 1.5 ms, don’t exceed 300 BPM.
• If the display shows
ERR
instead of the actual tempo or the BPM
led flashes irregularly, please check your wiring. Ground loops
and exceptionally high noise floor might distort the sync signal
as well as excessive levels above 10 dBu.
If you have ensured proper wiring, you can adjust both the Audio
Threshold of the
multiclock
(p. 15) or audio level on the sound-
card.