Manual SCA-SS-70-10
V 2.3
01/04 page 3
e-motion Gesellschaft für Antriebstechnik mbH, Zettachring 2, D-70567 Stuttgart, Germany
Tel.:+49-(0)711-7221535, Fax.:+49-(0)711-7221548 E-mail:[email protected]
1.9. EMC
the SCA-SS-70-10 is corresponds to the EC directives, standards and regulations 89/336/EWG article
10 and appendix 1 (EMV) amended by 92/31/EWG and 93/68/EWG and meet the requirements with
standard EN 61800-3 (1996) if the following directions are observed:
•
usage of a zinc plated mounting plate, well connected to earth
•
mounting of the drive by usage of toothed washers
to get a save electrical connection to „Power GND“/ Earth .
•
usage of shielded cables (less then 10m) to and from the unit
•
large area contact of the shielding with zinc plated mounting plate.
•
motor housing properly connected to earth
the user have to consider application specific features
2. Specification
Power supply voltage
11- 70 V DC
Current (impulse)
20 A
Current (nominal)
10 A
Frequency of power output stage
49 kHz ( +- 10%)
Efficiency
95 %
Bandwidth of current controller
2,5 kHz
2.1. Electrical
data
Internal choke
370 µH
Set value
-10...+10 V
Encoder input signals
Channel A, B; TTL max. 100 kHz
Tacho
Max 50 VDC(100kOhm)
Enable
Enable 8-30 V
limit switch „Disable Rev“
Disable 8-30 V
2.2. Inputs
limit switch „Disable Fwd“
Disable 8-30 V
Current monitor „Monitor I“
0,5V/A
Speed monitor „monitor n“
0,1V/V
Supervision output Ready
Open Collector max. 30 V DC
Supervision output Error
Open Collector max. 30 V DC
Auxiliary voltage source –15 V 20mA
max. 20mA
Auxiliary voltage 15 V 20 mA
max. 20 mA
2.3. Outputs
Auxiliary voltage 5 V 100 mA
Voltage supply for encoders
2.4. Display
2-colour LED
Green: ready red: error
2.5. Weight
With terminal connector
650 g
2.6. Dimensions
(DxWxH)
180 x 100 x 40 mm
Operation
-10...+45
o
C
2.7. Temperature-
range
Storage
-40...+80
o
C
2.8. Humidity
range
Non condensing
20% -80% rel. hum.