INSTALLATION: (see the diagram) 

 

Unclip the faceplate of sensor with a small flat blade screwdriver and adjust the time and 

LUX adjusters (refer to figure 1) 

 

Connect  the  cables  to  the  corresponding  terminals  and  ensure  there  are  no  loose 

connections. 

 

Install back the faceplate, switch on the power and then test it. 

 

 

 

 

 

Figure1                                            Figure2                                  Figure3 

CONNECTION-WIRE DIAGRAM: 

 

 

 

 

 

 

 

TEST: 

  Turn  the  LUX  adjuster  clockwise  on  the  maximum 

(sun).  Turn  the  SENS  adjuster  clockwise  on  the 

maximum  (+).Turn  the  TIME  adjuster  anti-clockwise 

on the minimum (10s).

 

 

 

When you switch on the power, the light will be on at 

once.  And  10sec±3sec  later  the  light  will  be  off 

automatically.  Then  if  the  sensor  receives  induction 

signal again, it can work normally. 

  When the sensor receives the second induction signals 

within the first induction, it will restart to time from the moment. 

 

Turn LUX adjuster anti-clockwise on the minimum (3). If the ambient light is less than 3LUX 

(darkness), the inductor load could work when it receives induction signal. 

Note: when testing in daylight, please turn LUX adjuster to        (SUN) position, otherwise 

the sensor lamp could not work! 

IMPORTANT NOTES

 

  Must be installed by a skilled competent electrician. 

  Ensure the AC supply is isolated. 

  Ensure sensor if located on a solid object free from any vibration of movement 

  Avoid installing it near the metal and glass which may affect the sensor. 

  Never modify the sensor as there are no user serviceable parts inside.   

  Not suitable for use with dimmer switches.   

  Install in accordance with I.E.C. Wiring Regulations   

  Fault Finding Tips: 

  The load doesn’t work: 

a. Check the power and the load. 

b. Whether the indicator light is turned on after sensing? If yes, please check load. 

c.  If  the  indicator  light  is  not  on  after  sensing,  please  check  if  the  working  light 

corresponds to the ambient light.   

d. Please check if the working voltage corresponds to the power source. 

  The sensitivity is poor: 

a.  Please  check  if  in  front  of  the  sensor  there  shouldn’t  be  obstructive  object  that 

affect to receive the signals. 

b. Please check if the signal source is in the detection fields. 

c. Please check the installation height. 

  The sensor can’t shut automatically the load: 

a. If there are continual signals in the detection fields. 

b. If the time delay is set to the longest. 

c. If the power corresponds to the instruction. 

 

 

 