4

JACK port. 

from devices such as 

pick-up. 

LAN

 

Network port  

Ethernet port  

z

 Connect 

to 

standard Ethernet 

cable.  

z

 Support 

PoE 

function. 

OPT 

100M fiber port  

155M single fiber 

dual-direction SFP 

fiber module  

Transmit 100M 

Ethernet data. 

SD 

SD card port  

 

Connect to SD card.  

Note 

z

 

When you install 

the SD card, 

please make sure 

current card is not 

in write mode and 

then you can 

install it to the 

camera. 

z

 When 

you 

remove the SD 

card, please 

make sure current 

card is not in write 

mode. Otherwise 

it may result in 

data loss or card 

damage. 

z

 

Before hot swap, 

please stop 

record operation. 

eLineTechnology.com

Summary of Contents for ELI-DFB-20

Page 1: ...Megapixel Indoor IPC Quick Start Guide Version 3 0 0 eLineTechnology com...

Page 2: ...mperature ranges from 10 to 60 Please keep it away from the electromagnetic radiation object and environment Please keep the sound ventilation Do not allow the water and other liquid falling into the...

Page 3: ...ii Accessory Name Amount IPC Unit 1 C CS adapter 1 Quick Start Guide 1 CD 1 eLineTechnology com...

Page 4: ...2 2 SD Card 8 2 2 1 Installation 8 2 2 2 Remove 9 2 3 3G Card 9 2 3 1 Installation 9 2 3 2 Remove 10 2 4 3G WIFI Antenna 11 2 4 1 Installation 11 2 4 2 Remove 12 2 5 I O Port 12 2 5 1 Install and Remo...

Page 5: ...iv Appendix Toxic or Hazardous Materials or Elements 21 eLineTechnology com...

Page 6: ...igure 1 1 The rear panel with the network port The rear panel with the 100M fiber port Figure 1 1 Please refer to the following sheet for detail information Interface Name Connector Function VIDEO OUT...

Page 7: ...light is on z Display record status Record green light flashes STATUS Indication Light Yellow light z Detect the wireless device yellow light is on 3G Connect to 3G card Please note it is for 3G serie...

Page 8: ...receive end TX RS232 port RS232_TX RS232 COM send out end G GND RS232 ground end NA IR light port External IR light signal control port RESET RESET button Restore factory default setup When system is...

Page 9: ...dule Transmit 100M Ethernet data SD SD card port Connect to SD card Note z When you install the SD card please make sure current card is not in write mode and then you can install it to the camera z W...

Page 10: ...m strike 1 2 Side Panel Please refer to the following interface for side panel dimension information The unit is mm See Figure 1 2 Figure 1 2 1 3 Front Panel Please refer to the following interface fo...

Page 11: ...6 Figure 1 3 eLineTechnology com...

Page 12: ...hen turn counter clockwise to move the focusing ring out for several millimeters Now you can focus manually and check the video is clear or not If you can not see the clear video you can adjust via th...

Page 13: ...on cap back to protect the CCD Figure 2 3 2 2 SD Card 2 2 1 Installation Please follow the steps listed below to install SD card The interface is shown as in Figure 2 4 and Figure 2 5 z Use the screwd...

Page 14: ...Remove the cap from the camera z Follow the SD card direction to remove the SD card z Insert the SD card protection cap z Use the screwdriver to fix the screw to secure the protection cap Figure 2 6...

Page 15: ...card protection cap screw firmly to secure the 3G card protection cap Figure 2 7 Figure 2 8 2 3 2 Remove Please follow the steps listed below to remove 3G card The interface is shown as Figure 2 9 z U...

Page 16: ...e rear panel See Figure 2 10 Please turn according to the direction in the following figure until antenna is secure firmly See Figure 2 11 Figure 2 10 Figure 2 11 After you fix the 3G WIFI antenna to...

Page 17: ...e following figure See Figure 2 13 Now you can see the antenna is away from the thread See Figure 2 14 Figure 2 13 Figure 2 14 Remove the 3G WIFI antenna from the port of the rear panel See Figure 2 1...

Page 18: ...igure for alarm input information See Figure 2 17 Alarm input When the input signal is idle or grounded the device can collect the different statuses of the alarm input port When the input signal is c...

Page 19: ...or external IR light information See Figure 2 19 IR synchronization input signal When the external IR light is on the signal cable from the board outputs the 3 3V 1mA It outputs the 0V when the IR lig...

Page 20: ...to the IP addresses in the same segment 3 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 3 1 In the device list interface you can view device IP addre...

Page 21: ...you can select an IP address and then click the Login button to go to the login interface See Figure 3 4 In Figure 3 4 you can view device IP address user name password and port Please modify the cor...

Page 22: ...Figure 3 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD eLineTechnology c...

Page 23: ...ult IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection is OK or not 4 2 Login and Logout Open IE and input IP camera...

Page 24: ...K button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the...

Page 25: ...20 Figure 4 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction eLineTechnology com...

Page 26: ...use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environm...

Reviews: