Chapter 5, Operating Instructions: Using the Drive Motors
E.H. Wachs
Part No. 81-MAN-00, Rev. C
49
Figure 5-27. Put the air motor fl ange over the screws in the motor adapter.
2.
Rotate the air motor to secure the screw heads in the slotted holes of the fl ange. Using a 1/4”
hex wrench, tighten the screws securely.
Figure 5-28. Turn the fl ange to seat the screws in the slots, then tighten the screws.
3.
Make sure the air supply is turned off at the source. Connect the air line to the connector on
the air motor.
4.
Turn on the air supply at the source.
5.
To operate the EP 424, squeeze the trigger on the air motor. The machine (form tool head or
single-point slide) will start to rotate.
NOTE
The air supply must provide 95 cfm at 90 psi (2700 l/min at 6.2 bar).