Operating manual EE100Ex Humidity / Temperature sensor for intrinsically safe applications

ENGLISH

1  General

This operation manual serves for ensuring proper handling and optimal functioning of the device. The 

operation manual and safety guide shall be read before commissioning the equipment and it shall be 

provided to all staff involved in transport, installation, operation, maintenance and repair.

The operation manual may not be used for the purposes of competition without the written consent of 

E+E Elektronik® and may not be forwarded to third parties. Copies may be made for internal purposes. 

All information, technical data and diagrams included in these instructions are based on the information 

available at the time of writing.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.2  Safety Instructions

1.2.1  General Safety Instructions

•  Avoid any unnecessary mechanical stress and inappropriate use.

•  When replacing the filter cap make sure not to touch the sensing elements.

•  For sensor cleaning and filter cap replacement please see “Cleaning instructions” at www.epluse.com.

•  Installation, electrical connection, maintenance and commissioning shall be performed by qualified 

personnel only.

1.2.2  Mounting, Start-up and Operation

The device has been produced under state of the art manufacturing conditions, has been thoroughly 

tested and has left the factory fulfilling all safety criteria.

The manufacturer has taken all precautions to ensure safe operation of the device. The user must  

ensure that the device is set up and installed in a manner that does not have a negative effect on its 

safe use.

The user is responsible for observing all applicable safety guidelines, local and international, with

respect to safe installation and operation on the device. This operating manual contains information

and warnings that must be observed by the user in order to ensure safe operation.

•  Mounting, start-up, operation and maintenance of the device may be performed by qualified staff only.

•  Such staff must be authorized by the plant operator to carry out the mentioned activities.

•  The qualified staff must have read and understood the operating manual and the safety guide and 

must follow the instructions contained within.

•  All process and electrical connections shall be thoroughly checked by authorized staff before putting 

the system into operation.

•  Do not install or start-up a device supposed to be faulty. Make sure that such devices are not  

accidentally used by marking them clearly as faulty.

•  A faulty device may only be investigated and possibly repaired by qualified, trained and authorized 

staff. If the fault cannot be fixed, the device shall be removed from the system.

•  Service operations other than described in this operating manual may only be performed by the  

manufacturer.

Summary of Contents for EE100EX

Page 1: ...v1 0 Technical data subject to change 194858 Operating Manual Bedienungsanleitung EE100Ex Humidity Temperature Sensor for Intrinsically Safe Applications Feuchte Temperatur Sensor f r eigensichere An...

Page 2: ...riebenen Produkte jederzeit zu modifizieren bzw abzu ndern Copyright E E Elektronik Ges m b H Alle Rechte vorbehalten E E Elektronik Ges m b H doesn t accept warranty and liability claims neither upon...

Page 3: ...ns 12 4 3 2 Return to factory setup 12 5 Status LEDs 12 6 Replacement Parts Accessories 12 7 Technical Data 13 DEUTSCH 1 Allgemein 14 1 1 Symbolerkl rung 14 1 2 Sicherheitshinweise 14 1 2 1 Allgemeine...

Page 4: ...on maintenance and commissioning shall be performed by qualified personnel only 1 2 2 Mounting Start up and Operation The device has been produced under state of the art manufacturing conditions has b...

Page 5: ...vice must be separated according to local recycling regulations The electronics shall be disposed of correctly as electronics waste 1 4 ESD Protection The sensing elements and the electronics board ar...

Page 6: ...order issued to the manufacturer The manufacturer assumes no liability for damages incurred due to failure to comply with the applicable regulations operating instructions or the operating conditions...

Page 7: ...ly safe applications 2 4 Dimensions in mm inch 2 4 1 Model T1 Wall Mount 163 6 42 90 3 54 48 1 89 70 2 76 L Fig 1 Dimensions Model T1 2 4 2 Model T3 Remote Sensing Probe with Fixed Cable 1 0 6 4 1 7 L...

Page 8: ...140 F L filter cap Length in mm Stainless steel sinter filter 33 1 3 PTFE filter H2O2 filter 33 1 3 Stainless steel grid PTFE filter 39 1 5 Membrane filter 34 1 4 2 5 Installation The EE100Ex has been...

Page 9: ...on water getting along the cable to the sensing probe a drip loop shall be realized close to the probe Horizontal mounting Vertical mounting Fig 5 Correct mounting position For accurate measurement re...

Page 10: ...rer s representative for advice 2 5 3 Mounting with Mounting Flange optional The mounting flange may only be used for installing the probe in separating walls between two explosion hazard areas of the...

Page 11: ...e firmware update cannot be carried out for a connection via the RS232 interface 4 1 Configuration 4 1 1 Output Scale The 4 20 mA outputs of the EE100EX are factory scaled according to the order The u...

Page 12: ...adjustment of the device but does not affect the user setup for measurand output scale and error indication 5 Status LEDs The EE100Ex features two status LEDs on the electronics board see Fig 8 Status...

Page 13: ...00mA Pi 700mW Ci 2 2nF Li 0mH Electrical connection Screw terminals max 1 5 mm Cable glands M16 for cable diameter 4 5 10 mm 0 18 0 4 M20 for cable diameter 10 14 mm 0 4 0 55 Protection class IP65 Wor...

Page 14: ...onal durchgef hrt werden 1 2 2 Montage Inbetriebnahme und Betrieb Das Ger t wurde mit den modernsten Fertigungsbedingungen hergestellt gr ndlich getestet und erf llt beim verlassen des Werkes alle Sic...

Page 15: ...f die sortenreine Trennung der einzelnen Komponenten geachtet werden Die Elektronik muss im Elektronikschrott gesammelt und fachgerecht entsorgt werden 1 4 ESD Schutz Die Sensorelemente und die Platin...

Page 16: ...Betrag der dem Hersteller erteilten Bestellung begrenzt Der Hersteller bernimmt keine Haftung f r Sch den die durch Nichtbeachtung geltender Vorschriften Betriebsanleitungen oder bedingungen entstehe...

Page 17: ...chere Anwendungen 2 4 Abmessungen in mm inch 2 4 1 Modell T1 Wandmontage 163 6 42 90 3 54 48 1 89 70 2 76 L Abb 1 Abmessungen Modell T1 2 4 2 Modell T3 Abgesetzter F hler mit fixem Kabel 1 0 6 4 1 7 L...

Page 18: ...ungskabel 25 60 C L Filterkappe L nge in mm Edelstahlsinterfilter 33 1 3 PTFE Filter H2O2 Filter 33 1 3 Edelstahlgitterfilter 39 1 5 Membranfilter 34 1 4 2 5 Installation Der EE100Ex ist zertifiziert...

Page 19: ...des Kabels zum F hler gelangt sollte bei jeder Montage ein Abtropfbogen gelegt werden Horizontale Montage Vertikale Montage Abb 5 Richtige Montageposition F r genaue Messresultate ist es erforderlich...

Page 20: ...den Vertriebspartner des Herstellers 2 5 3 Montage mit Montageflansch optional Der Montageflansch darf nur f r die Installation des F hlers in Trennw nden zwischen zwei explosions gef hrdeten Bereich...

Page 21: ...elle kann das Firmwareupdate nicht durchgef hrt werden 4 1 Konfiguration 4 1 1 Ausgabeskalierung Die 4 20 mA Ausg nge des EE100Ex sind werkseitig gem der Bestellung skaliert Bei Bedarf kann diese ge n...

Page 22: ...urspr ngliche Justage des Ger tes wieder her Dies hat jedoch keinen Einfluss auf die benutzerdefinierten Einstellung f r Messgr en Ausgangsskalierung und Fehleranzeige 5 Status LEDs Der EE100Ex verf g...

Page 23: ...cherheitsfaktoren Ui 28V Ii 100mA Pi 700mW Ci 2 2nF Li 0mH Elektrischer Anschluss Schraubklemmen max 1 5 mm Kabelverschraubung M16 f r Kabeldurchmesser 4 5 10 mm 0 18 0 4 M20 f r Kabeldurchmesser 10 1...

Page 24: ...0 6460 Office Stuttgart Tel 49 151 538 37 500 E E Elektronik Italy info epluse it Tel 39 02 2707 86 36 E E Elektronik France info epluse fr Tel 33 4 74 72 35 82 E E Elektronik USA office epluse com Of...

Reviews: