INSTALLATION INSTRUCTIONS
E-SBA7 Series
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before
installation.
DANGER
– Risque de choc – Couper l’alimentation
avant l’installation.
2. This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n’êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3. Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
7. Strain relief is required for electrical connection on 2" (51 mm)
adjustable fitter mounts at heights of 25' (7.6 mm) and above. Tie
a knot in the supply wires above the supply wire entry hole in the
splice compartment to reduce the strain on the connections. Make
sure the knot will not slip through the hole.
8.
Slip lower fitter over 2 - 3/8" (60 mm) o.d. heavy wall pipe or tenon
and securely tighten two Allen head set screws with 3/16" Allen
wrench to 140 in-lbs (16 Nm). See
Figure 1.
9.
Connect the black fixture lead to the voltage supply lead. Connect
the white fixture lead to the neutral supply lead. Connect the green
fixture lead to the supply ground.
10. If photocell accessory is used, locate it in the cover of the fitter
supply compartment. See photocell installation sheet for details.
11.
Fixture is intended for mounting orientations from 0°- 180° tilt. See
Figure 2.
12.
Tighten 3/8" bolt in fitter splice compartment to 19 ft-lbs (25 Nm).
13.
Replace fitter splice compartment cover and tighten (2) screws
that were removed in Step 5.
14.
Reinstall driver housing cover plate by replacing it on top of
housing and tightening (6) screws that were removed in Step 1.
Yoke Mount with 5/16"
(8 mm) bolts to strong
solid surface
.
5/16" (8 mm) bolts
2" (51 mm) Adjustable Fitter
over 2" (51 mm) pipe.
2" (51 mm)
Adjustment Screw
Allen Head
Set Screws
FIGURE 1
FIGURE 2 - 2" (51 mm) Adjustable Fitter Position
Note:
Use this fixture installation sheet for installing. DO NOT refer to
mounting accessory sheet for installing.
1.
Remove the six screws on the top of the fixture housing to allow
removal of the driver housing cover plate.
2.
Install gasket on upper fitter by aligning the (2) holes in the gasket
with the (2) threaded holes in the upper fitter.
3.
Align (2) threaded bolt holes on the upper fitter with the (2) bolt
holes in the side of the fixture.
4.
Fasten upper fitter to the fixture using the (2) bolts and lock
washers supplied with the fitter. Tighten bolts to 132 in-lbs (15
Nm)
5.
Remove splice compartment cover from upper fitter by removing
(2) screws on cover.
6. Route fixture ground wire (green), common wire (white), and hot
wire (black) through wall of fixture and into the splice compartment
of fitter.
2" (51 mm) ADJUSTABLE FITTER MOUNTING
Typical Pole Mounted Positions
Major Divisions: 15˚
30˚
30˚
30˚
30˚
15˚
0˚
15˚
75˚
45˚
90˚
180˚
30˚
30˚