background image

INSTALLATION INSTRUCTIONS

E-MT5, E-MT6, AND E-MT7 SERIES

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should
always be followed including the following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1. Make certain power is OFF before starting installation or

attempting any maintenance.

2. Fixture comes standard with a HOT, COMMON and GROUND

wire or ground lug.

3. 90°C supply wire required for E-MT5A301G. All others require

60°C supply wire.

4. Mounting locations above 4 feet (1.2 meters), caulking of

canopy to mounting surface and fixture must not be used
without lamp shields

SAVE THESE  INSTRUCTIONS

Turn off power supply to avoid the risk of electrical shock. This
product must be wired in accordance with the National Electrical
Code and applicable local codes and ordinances. Proper grounding
is required to ensure personal safety. A qualified electrician should
do all work.

CAUTIONS

1. Remove (3) screws connecting the pendant mounting/ballast

cover to the fixture housing. 

2. Thread the pendant mounting cover onto the conduit.
3. Complete the wiring to the power source (refer to wiring

instructions) 

4. Seal around the conduit using approved NEC procedures. 
5. If necessary, align gasket with holes in fixture housing.
6. Reinsert and tighten (3) screws connecting the pendant mounting

cover to the fixture housing.

MOUNTING TO CONDUIT PENDANT MOUNTING

(E-MTA AND E-MT6 SERIES)

Document

Date

Drawing/Page

DCR#

CI308X10R1
JAD

10-162

08/02/10

w w w.  e - c o n o l i g h t . c o m

8 8 8 . 2 4 3 . 9 4 4 5

FA X :  2 6 2 . 5 0 4 . 5 4 0 9

1. Remove (3) screws connecting the ballast cover to the fixture

housing.

2. Remove (2) screws connecting the ballast cover to the

Mounting Arm.

3. Remove (4) screws connecting the mounting arm to the J-box. 
4. Attach the J-Box to the mounting surface.
5. Attach conduit to J-box and pull leads to the box.
6. Seal around the conduit using approved NEC procedures.
7. Complete the wiring to the power source (refer to

wiring instructions).

8. Reassemble fixture by reversing steps 1, 2 & 3.

NOTE: Make sure to properly align gaskets between the
mounting and ballast cover and between the ballast cover
and fixture when reassembling.

WALL MOUNTING (E-MT7 SERIES)

E-MT6A301G

E-MT7A301G

E-MT5A301G

E-MT7F421G

E-MT7M07DG

E-MT7H151G

E-MT6F421G

E-MT6M07DG

E-MT6H151G

E-MT5F421G

E-MT5M07DG

E-MT5H151G

1. Remove (3) screws connecting the ballast cover to the

fixture housing.

2. Remove (2) screws connecting the ballast cover to the J-box.
3. Attach the J-box to the mounting surface.
4. Attach conduit to J-box and pull leads to the box.
5. Seal around the conduit using approved NEC procedures.
6. Complete the wiring to the power source (refer to

wiring instructions.)

7. Reassemble fixture by reversing steps 1 & 2.

NOTE: Make sure to properly align gasket between the ballast
cover and fixture when reassembling.

CEILING MOUNTING (E-MT5 SERIES)

1. Loosen guard set screws.
2. Remove globe and guard assembly.
3. Install recommended lamp only.
4. Re-install globe and guard assembly.
5. Tighten guard set screws.

LAMP INSTALLATION