13
Connection of Horizontal (060/lOOmm) Hermetic Flue Set to the Combi Boiler
As your combi boiler is hermetic model, it takes the air used from the external environment, and
discharges the waste gases arising as the result of combustion from the same flue group. The use
and assembly of flue is very important for the extremely harmful waste gases not to be spread in
the environment, thus the warnings should be considered while making the flue connections.
Horizontal outlets should be assembled with 1-2% downwards inclination for
rain water etc. not to enter the device. (Figure Sa)
Horizontal (
Ø
60/100 mm ) Hermetic Flue Set Consists of the Following Parts;
1. Flange gasket
2. Flue connection flange
3. Flange screws
4. Sealing gasket
5. 90
°
bend
6. Clamp
7. Clamp screws
8. EPDM connection gasket
9. Flue outlet terminal
10. Interior wall connection flange
11. Exterior wall connection flange(EPDM)
Figure 8
• Make the required flue selection for the flue connection to be made to outer environment from
the location where your combi boiler is assembled. If the standard flue set is insufficient, select
the most suitable accessories from our connection accessories list considering the warnings
referred in our guide.
• Fix the flue connection flange through screwing to the holes on the combi boiler by using the
flange gasket. (Figure 9a-9b)
• Place the 2 sealing gaskets -provided by the hermetic flue set- to interior pipe slots on both ends
ofthe bend of 90
°
.
• Apply the EPDM connection gasket to the bend of 90
°
as to contact the limiting set inside the
gasket.
• In order to group the flue outlet terminal, apply the exterior wall (EPDM) gasket to flue terminal
as seen in Figure 9c. After passing the flue outlet terminal through the exterior side of the wall
and from the previously opened hole, connect the interior wall connection gasket to flue
terminal. Apply the other end of the EPDM connection gasket of your combi boiler -which is
applied to flue bend of 90
°
- to the flue outlet terminal, and apply the clamp on the EPDM
connection gasket and loosely tighten it with screw (Figure 9d). And then place the bend of 90
°
on the flue connection flange, and fix with tightening screws (Figure 9e). Finally, after tightening
the screws which are placed on EPDM gasket and which are left loose, enable the flue and wall
tightness by pushing the interior wall connection gasket as to touch the wall.
Summary of Contents for GeliosPlus 11
Page 2: ...30 11 10 18 18 19 ...
Page 10: ...Min distancetothe roof Human area Vehicle area ...
Page 18: ...16 3 6 7 1 2 4 5 ...
Page 19: ...43 GELIOS PLUS 24 20 kW 17 39 GELIOS PLUS 16 13 11 kW 5 4 3 4 5 5 4 3 4 5 ...
Page 22: ...20 Figure 18a Option 1 Figure 18b Option 2 67 66 ...
Page 23: ...21 ...
Page 25: ...23 ...
Page 27: ...Flame Signal 25 30 CH Pressure Value ...
Page 28: ...26 ...
Page 29: ...27 12 3 1 4 28HM 11 9 1 25 ...
Page 30: ...28 For 28 kW there are 13 injectors on the boiler ...
Page 31: ...Error Maltunction Codes 29 9 ...
Page 32: ...30 F1 Overtemperature locking 9 ...
Page 33: ...950mm 1 740mm 8 3 3 31 ...
Page 34: ...320mm for 28 kW 5m 32 ...
Page 36: ...34 7006907068 1 0 ...