13.3
Basic parameter
Readout via electrical interface.
Access Level
R: read only
R/W: read/write
R/W(M): write only in manufacturer mode (meter cover opened
)
OBIS
Property,
value range and default value
Type of
access
01- 00: 5E.31.00*01
Time information
The time information is filed as a seconds index (see Clause 5.1.7).
R
01-00:5E.31.01*01
Enable/disable the active power indication on the display.
Using ‘TRUE’ the active power output on the display is turned on.
Value range: TRUE/FALSE
Default value: FALSE
R/W
01-00:5E.31.01*02
Enable/disable the output of a manufacturer-specific dataset on the INFO inter-face.
Using ‘TRUE’ the output of the manufacturer-specific dataset is turned on.
Value range: TRUE/FALSE
Default value: FALSE
R/W
01-00:5E.31.01*03
Number of magnetic sensor manipulation
events detected.
Value range: 0 to (2161)
Default value: 0
R
01-00:5E.31.01*04
Enable/disable/reset of manipulation detection
By means of writing using ‘TRUE’ a status bit possibly set for manipulation
detection will be reset thus enabling the manipulation detection. By means of
writing using ‘FALSE’ the manipulation detection is disabled and the counter for
magnetic manipulation detection is set to ‘0’. The last valid condition is restored
when the voltage supply is reconnected.
Value range: TRUE/FALSE
Default value: FALSE
R/W
01-00:5E.31.01*09
Enable/disable reset of manipulation detection for mechanical manipulation
(terminal cover or locking pin)
By means of writing using ‘TRUE’ a status bit possibly set for manipulation
detection will be reset thus enabling the manipulation detection.
By means of writing using ‘FALSE’ the manipulation detection is disabled and the
counter for mechanical manipulation detection is set to ‘0’. The last valid condition
is restored when the voltage supply is reconnected.
Value range: TRUE/FALSE
Default value: FALSE
R/W
01-00:5E.31.01*0A
Number of mechanical manipulation events detected.
Value range: 0 to (2161)
Default value: 0
R
01-00:60. 32.01*01
Manufacturer ID
(see FLAG association)
R
01-00:60.01.00*FF
Device identification
(see DIN 43863-5)
R
01-00:00.02.00*00
Device firmware version
R
01-00: 60. 5A.02*01
Firmware checksum in accordance with MID
R
01-00:01.08.00*FF
Meter reading for active energy in the dirA
R
01-00: 02.08.00*FF
Meter reading for active energy in the direction -A
R
01-00:20.07.00*FF
Metered voltage for L1
R
01-00:34.07.00*FF
Metered voltage for L2
R
01-00:48.07.00*FF
Metered voltage for L3
R
01-00:10.07.00*FF
Instantaneous active power
R
01-00:60.05.00*FF
Status word
R
01-00:5E.31.01*06
Access protection via PIN code
If ‘true’, the option of data protection via
PIN code is enabled.
R/W
01-00:5E.31.01*07
PIN code
R/W
01-00:5E.31.01*08
Enabling/disabling the indication of historic consumption values on the display
R/W
01-00:01.08.00:60
Historic consumption value for the daily consumption (d)
R
01-00:01.08.00*61
Historic consumption value for the weekly consumption (w)
R